6ES7516-3AP03-0AB0
Siemens
| Availability: | |
|---|---|
| Quantity: | |
Three interfaces, three different jobs. X1 is the machine network: two RJ45 ports behind an integrated switch, PROFINET IRT with isochronous mode, up to 256 IO devices — 64 of them IRT-capable — and a refresh of 250 µs to 4 ms at a 250 µs send clock. X2 is a single port without a switch, with its own IP address and subnet, PROFINET RT only: 32 IO devices, shared device operation with up to four IO controllers, and no IRT or isochronous mode. In practice X2 carries the HMI, the line-level SCADA link or the connection to the plant backbone, so the machine network stays closed without an external router. X3 is the PROFIBUS DP master — RS485, up to 12 Mbit/s, 125 DP slaves, 48 connections, equidistant and isochronous mode supported. All three run at the same time, which is the real argument for this CPU in retrofit work: legacy DP drives and DP remote IO stay on X3, new servo drives and ET 200SP stations go on X1, and the higher-level system is served on X2 — no additional communication module required.
Memory and program structure. 2 MB of program memory and 7.5 MB of data memory hold up to 8 000 elements (OB, FB, FC, DB, UDT), with a single OB, FB or FC up to 1 MB and a data block up to 7.5 MB (64 KB when absolutely addressed). OB resources are wider than on the 1515: 100 free-cycle OBs, 20 time-of-day, 20 delay and 20 cyclic interrupts down to 250 µs, 50 process interrupts, three DPV1 interrupts, three isochronous OBs and 100 startup OBs. At 6 ns per bit instruction, 7 ns per word, 9 ns for fixed-point and 37 ns for floating-point arithmetic, logic, closed-loop control and motion can share one cycle rather than being split across controllers. The retentive area is 512 KB, of which 472 KB is usable for retentive bit memory, timers, counters, DBs and technology data; with the PS 60 W 24/48/60 V DC HF power supply it can be extended to 7.5 MB. The I/O address area is 32 KB in and 32 KB out, a rack takes up to 32 modules, and up to 64 distributed I/O systems can be configured.
Motion, diagnostics and IT integration. Motion control is integrated with 2 400 resources — roughly eleven positioning axes at a 4 ms motion control cycle, twenty at 8 ms, plus external encoders, output cams, cam tracks and probes. Three isochronous OBs give more headroom for multi-axis interpolation and cam synchronism than the 1515 offers. PID_Compact, PID_3Step and PID-Temp cover the temperature, pressure and flow loops that usually sit beside the axes. Diagnostics go past the fault LED: the display names the faulty module and channel, the 3 200-entry diagnostic buffer is readable in TIA Portal or through the web server, and four traces record signal waveforms inside the controller — no oscilloscope or external logger needed for intermittent faults. OPC UA server (48 sessions, up to 100 000 accessible variables) and client (10 connections), HTTPS web server, Modbus TCP and NTP make the CPU a direct data source for MES and higher-level systems without a gateway — subject to the OPC UA runtime licence "Medium".
① Three interfaces: 2× PROFINET + PROFIBUS DP
X1 IRT with 2-port switch (256 IO devices, 64 IRT); X2 RT with its own IP (32 devices, shared device); X3 DP master (12 Mbit/s, 125 slaves, 48 connections).
② 2 MB / 7.5 MB work memory
8 000 elements, 1 MB blocks, 7.5 MB data blocks; 512 KB retentive area (472 KB usable), extendable to 7.5 MB with the HF power supply.
③ 6 ns bit performance
6 ns bit, 7 ns word, 9 ns fixed-point, 37 ns floating-point — a clear step up from the 10 ns of the previous AN02.
④ 2 400 motion control resources
About 11 positioning axes at 4 ms or 20 at 8 ms; three isochronous OBs, cams, cam tracks and measuring probes.
⑤ Ring redundancy and isochronous mode
MRP / MRP interconnection / MRPD, typical 200 ms switchover, up to 50 nodes per ring; distributed isochronous OB from 375 µs.
⑥ Display, OPC UA, web server
6.1 cm display, 8 keys and 2 mode buttons; OPC UA server 48 sessions / client 10 connections, HTTPS, Modbus TCP (licence "Medium").
General | |
Product type | CPU 1516-3 PN/DP (standard CPU, not fail-safe) |
Hardware version | FS04 |
Firmware version | V4.1 (updateable); earlier batches may ship V3.1 / V4.0 |
Engineering software | TIA Portal V21 (FW V4.1) / V18 (FW V3.0) or higher; older TIA versions configure it as 6ES7516-3AN02-0AB0 |
Dimensions (W × H × D) | 70 × 147 × 129 mm |
Weight | approx. 0.47 kg |
Mounting / degree of protection | S7-1500 profile rail / IP20 |
Memory | |
Work memory, program | 2 MB |
Work memory, data | 7.5 MB |
Load memory | SIMATIC Memory Card, max. 32 GB (required, 1 slot) |
Retentive data area | 512 KB max., of which 472 KB usable; extendable to 7.5 MB with PS 60 W 24/48/60 V DC HF |
Bit memory (M) | 16 KB max.; 8 clock memory bits |
Data block size | 7.5 MB (64 KB when absolutely addressed) |
OB / FB / FC size | 1 MB each |
Performance | |
Bit / word operations | 6 ns / 7 ns |
Fixed-point / floating-point | 9 ns / 37 ns |
Elements (OB, FB, FC, DB, UDT) | 8 000 total |
OBs available | 100 cyclic, 20 time-of-day, 20 delay, 20 cyclic (min. 250 µs), 50 process, 3 DPV1, 3 isochronous, 100 startup |
Nesting depth | 24 per priority class |
S7 counters / S7 timers | 2 048 / 2 048, retentivity adjustable |
IEC counters / timers | Unlimited, limited only by work memory |
I/O address area | 32 KB inputs / 32 KB outputs in the process image; 8 192 IO modules; max. 32 modules per rack |
Communication | |
Interface X1 | PROFINET IRT, 2× RJ45 with integrated switch, 100 Mbit/s |
Interface X2 | PROFINET RT, 1× RJ45, no switch, no IRT / isochronous mode; shared device with up to 4 controllers |
Interface X3 | PROFIBUS DP master, RS485, up to 12 Mbit/s, 125 DP slaves, 48 connections |
IO devices | X1: 256 (64 with IRT); X2: 32; up to 1 000 across AS-i / PROFIBUS / PROFINET |
IRT update time | 250 µs – 4 ms at a 250 µs send clock; isochronous OB min. 375 µs distributed / 1 ms central |
Redundancy | MRP / MRP interconnection / MRPD, typical switchover 200 ms, max. 50 nodes per ring |
Connections | 256 max. (128 on the integrated interfaces, 10 reserved for ES / HMI / web); 16 S7 routing paths |
OPC UA | Server: 48 sessions, 100 000 variables. Client: 10 connections. Runtime licence "Medium" required |
Web server / protocols | HTTP and HTTPS (standard and user pages), Web API 100 sessions; Modbus TCP; NTP; PROFIenergy |
Motion control | |
Resources | 2 400 (speed axis 40, positioning axis 80, synchronous axis 160, encoder 80, output cam 20, cam track 160, probe 40) |
Positioning axes (typical) | About 11 at a 4 ms motion control cycle; 20 at 8 ms |
Closed-loop blocks | PID_Compact, PID_3Step, PID-Temp with integrated optimization |
Power, display and environment | |
Rated supply | 24 V DC (19.2 – 28.8 V), reverse polarity protected; 5 ms power-fail buffering |
Current consumption | 0.69 A rated, 1.08 A max.; inrush 1.15 A max. |
Power loss / backplane | 4 W typ.; 12 W fed to the backplane bus, 6.7 W drawn from it |
Display | 6.1 cm, 8 keys and 2 mode buttons; switches off above 50 °C horizontal / 40 °C vertical |
Ambient temperature | −30 to +60 °C horizontal / −30 to +40 °C vertical |
Storage and transport | −40 to +70 °C; installation altitude up to 5 000 m (restrictions above 2 000 m) |
Q1. What is connected to each of the three interfaces?
X1 (two-port switch, IRT) takes servo drives and ET 200SP / ET 200MP remote IO that need real-time and isochronous behaviour — up to 256 devices, 64 of them with IRT. X2 is a single-port RT interface with its own IP address and subnet, for the HMI, line-level SCADA or the plant backbone: 32 devices, shared device with up to four controllers. X3 is the PROFIBUS DP master — RS485, 12 Mbit/s, 125 slaves, 48 connections, equidistant and isochronous mode. All three operate at once, which is the core advantage over the 1515-2 PN: existing DP devices stay where they are, with no extra communication module.
Q2. How does it differ from the previous 6ES7516-3AN02-0AB0 (or the earlier AN01)?
Three things changed: memory from 1 MB / 5 MB to 2 MB / 7.5 MB; speed from 10 ns to 6 ns per bit instruction (word 12 → 7 ns, floating-point 64 → 37 ns); and power loss from 7 W to 4 W typical, which matters in a sealed cabinet. The interfaces are unchanged — still two PROFINET plus DP. Coming from an AN01 (FS03), also check the width: the AP03 is 70 mm wide, so it takes more rail space than a 35 mm single-interface CPU.
Q3. Does the TIA Portal project have to be changed when replacing an older CPU?
The swap is direct, but watch the software version: the AP03 currently ships with firmware V4.1, which requires TIA Portal V21; V18 corresponds to FW V3.0; older TIA versions can configure the AP03 as a 6ES7516-3AN02-0AB0, in which case it behaves as the predecessor. In practice: back up the project and the memory card, replace the CPU, recompile the hardware configuration and download, then verify that PROFINET device names, IP addresses, DP slave addresses and the OPC UA / web server settings survived. Larger memory does not affect the existing program, but block size limits change, so run a consistency check afterwards.
Q4. Is the SIMATIC Memory Card mandatory?
Yes. The CPU has no integral load memory — program, hardware configuration, recipes and retentive data all live on the SIMATIC Memory Card (up to 32 GB). Order the card with the CPU, and keep a programmed spare card on site: after a controller failure, swapping the card is the fastest way back to production.
Q5. Can it run safety functions?
No. This is a standard CPU and does not support PROFIsafe. E-stop, guard doors, safe speed and safe torque off require the F-version 1516F-3 PN/DP with the matching F-DI / F-DO modules, engineered with the safety program in TIA Portal. Standard and safety programs can share an F-CPU, but not this one.
Q6. How many axes can it actually run?
Siemens quotes a resource model: 2 400 in total, with a positioning axis costing 80, a synchronous axis 160, a speed axis 40, an external encoder 80, an output cam 20, a cam track 160 and a probe 40. As planning figures, about eleven positioning axes at a 4 ms motion control cycle, or twenty at 8 ms. Gearing and camming consume resources much faster than plain positioning. Leave cycle headroom as well — technology objects are calculated alongside the user program, so the more axes, the less time is left for logic. Run the actual configuration through the TIA Selection Tool before committing.
Q7. What OPC UA licence is needed, and how many clients are supported?
The runtime licence "Medium" — the same level as the 1515-2 PN, one step above the "Small" licence of the 1513-1 PN. The server supports 48 sessions, up to 100 000 accessible variables and 50 subscriptions per session, with a minimum sampling interval of 100 ms; the client supports 10 connections. Without the licence the OPC UA server cannot be activated, although the web server, S7 communication and Modbus TCP continue to work. Buy the licence with the project — retrofitting means a separate order and a download window.
Q8. What is its lifecycle status?
PM300: Active — this is the current shipping version of the CPU 1516-3 PN/DP and can be specified for new projects. Its predecessor 6ES7516-3AN02-0AB0 was phase-out from 1 October 2024, and the AP03 is the official successor, so both new machines and installed-base replacements point to this article. Confirm lead time and stock per project with Siemens or your authorized distributor.