6ES7217-1AG40-0XB0
Siemens
| Availability: | |
|---|---|
| Quantity: | |
What the differential interface unlocks. On a standard S7-1200 CPU the 24 V DC single-ended inputs are limited by optocoupler and level swing, so high-speed counting typically stops at 100 kHz. The 1217C adds four RS-422/485 differential inputs and four differential outputs: 5 V differential signalling, steep edges and strong common-mode rejection push counting and pulse frequencies to 1 MHz. That means direct connection of 5 V differential incremental encoders for high-speed speed, length and position-latch measurement, and differential pulse/direction control of servo or stepper drives rated for 1 MHz pulse input — roughly an order of magnitude more motion capability in the same 150 mm width.
A hybrid I/O layout that keeps both worlds. The 14 inputs are not all 24 V DC: 10 are standard 24 V DC (sink/source selectable, usable for 100 kHz counting) and 4 are differential. The same applies to the 10 outputs — 6 at 24 V DC transistor 0.5 A, 4 differential. The benefit is that general-purpose and high-speed signals do not compete for channels: pushbuttons, limit switches and contactors stay on the 24 V DC side while encoders and pulse commands use the differential side, with no technology module to buy. The CPU also provides a 400 mA 24 V sensor/load supply for encoders and proximity switches.
Performance, memory and IT security. 250 KB work memory, 4 MB load memory and a 14 KB retentive area, with 0.08 µs bit instructions; six high-speed counters up to 1 MHz and four PTO channels support demanding process logic alongside 8 axis resources (4 of them via the pulse/direction interface). Communication is one interface with two RJ45 ports (integrated switch), covering PROFINET IO controller and device roles, MRP ring redundancy, an OPC UA server (up to 10 connections) and a web server. Firmware V4.7 also adds local user management — up to 42 users, 14 groups and 20 roles — so machine builders can implement access levels that satisfy increasingly common cybersecurity audits.
① 1 MHz high-speed counting
6 HSC channels, up to 1 MHz on the differential side (100 kHz at 24 V DC) for 5 V differential incremental encoders.
② Four 1 MHz pulse outputs
4 PTO channels up to 1 MHz differential (100 kHz at 24 V DC), PWM up to 100 kHz, up to 8 axis resources.
③ Hybrid I/O layout
14 DI (10 × 24 V DC + 4 differential) / 10 DO (6 × 24 V DC 0.5 A + 4 differential) — no channel contention.
④ 250 KB and two-port PROFINET
250 KB work memory, 4 MB load; 2 × RJ45 with integrated switch, 16 IO devices, MRP ring support.
⑤ 400 mA sensor supply
Integrated 24 V encoder/load supply delivers 400 mA for encoders and proximity switches — one less power supply.
⑥ OPC UA and user management
OPC UA server (up to 10 connections), web server, local user management (42 users / 14 groups / 20 roles).
General | |
Product type | CPU 1217C DC/DC/DC |
Firmware version | V4.7 |
Engineering software | STEP 7 / TIA Portal V20 or higher |
Programming languages | LAD, FBD, SCL |
Dimensions (W × H × D) | 150 × 100 × 75 mm |
Weight | approx. 490 g |
Mounting / degree of protection | 35 mm DIN rail or panel / IP20 |
Power supply | |
Rated supply voltage | 24 V DC (20.4 – 28.8 V), reverse-polarity protected |
Current consumption | 600 mA (CPU only); max. 1600 mA with all expansion modules |
Inrush current | max. 12 A at 28.8 V, I²t = 0.5 A²·s |
Backplane supply (5 V DC) | max. 1600 mA for SM / CM |
24 V encoder / load supply | 400 mA output current, can supply sensors and encoders directly |
Power loss | 12 W typ. |
Memory and performance | |
Work memory | 250 KB integrated, not expandable |
Load memory | 4 MB integrated; expandable with SIMATIC Memory Card |
Retentive data area | max. 14 KB (timers, counters, flags) |
Bit / word / floating-point | 0.08 µs | 1.7 µs | 2.3 µs |
Process image | 1 KB inputs / 1 KB outputs, adjustable |
Data backup | Maintenance-free, battery-free |
Onboard digital I/O | |
Digital inputs (14 total) | 10 × 24 V DC (sink/source selectable) + 4 × RS-422/485 differential (1.5 V DC differential level) |
Inputs usable as HSC | 6; up to 100 kHz at 24 V DC, up to 1 MHz differential |
Input delay | Parameterizable (0.1 µs – 20 ms depending on input type) |
Digital outputs (10 total) | 6 × 24 V DC transistor (sourcing, 0.5 A) + 4 × RS-422/485 differential outputs |
High-speed outputs / PTO | 4; up to 1 MHz differential, up to 100 kHz at 24 V DC |
PWM | 4 outputs, up to 100 kHz |
Output load (24 V DC side) | 0.5 A per point resistive; lamp load max. 5 W; inductive shutdown limited to L+ (−48 V) |
Onboard analog I/O | |
Analog inputs | 2 × 0 – 10 V DC, 10-bit resolution, input resistance ≥100 kΩ, conversion time 625 µs per channel |
Analog outputs | 2 × 0 – 20 mA DC, 10-bit resolution |
Analog cable length | max. 100 m, twisted and shielded |
Technology functions | |
High-speed counters | 6 channels up to 1 MHz (differential); incremental encoders, frequency measurement, position latching |
Positioning axes | up to 8 motion control axis resources; max. 4 via pulse/direction interface |
Closed loop / alarms | PID autotuning (up to 16 loops); 4 alarm inputs; trace and diagnostic buffer |
Communication | |
PROFINET interface | 1 interface / 2 × RJ45 ports, integrated switch, 100 Mbit/s, autonegotiation / autocrossover |
Roles and capacity | IO controller / IO device; up to 16 IO devices (8 activatable/deactivatable at runtime); MRP client |
Protocols | PROFINET IO, TCP/IP, ISO-on-TCP, UDP, MODBUS TCP, OPC UA, web server |
Connection resources | 68 total (34 reserved); up to 10 OPC UA connections |
User management | up to 42 users / 14 groups / 20 roles |
Expansion | |
Signal modules (SM) | up to 8 |
Signal / communication board | up to 1 (SB, CB, BB combined) |
Communication modules (CM) | up to 3 (e.g. CM 1241 RS-232/485, CM 1243-5 PROFIBUS DP master) |
Clock and environment | |
Real-time clock | Yes; 480 h typical backup; deviation ≤±60 s/month at 25 °C |
Ambient temperature | −20 to +60 °C horizontal; −20 to +50 °C vertical |
Derating at high temperature | Above 55 °C (horizontal) / 45 °C (vertical), simultaneously active channels drop to 14 / 10; at 60 °C / 50 °C to 7 / 5 (non-adjacent) |
Storage temperature / humidity | −40 to +70 °C / ≤95% non-condensing |
Approvals | CE, UL, cULus, FM Class I Div. 2, KC, RCM, marine approvals |
Q1: How does the 1217C differ from the 1215C, and is it worth the extra cost?
Four substantive differences: (1) differential I/O — the 1217C adds 4 RS-422 differential inputs and 4 differential outputs, raising counting and pulse limits from 100 kHz to 1 MHz; (2) memory — 250 KB versus 200 KB; (3) width — 150 mm versus 130 mm, with the same 12 W power loss but 600 mA CPU current versus 500 mA; (4) positioning — 4 axes at 1 MHz versus 4 axes at 100 kHz. For plain discrete control and low-speed positioning the 1215C is sufficient; as soon as the machine needs high-speed encoder length measurement, flying shear, registration or 1 MHz pulse servos, the 1217C is the only S7-1200 that can do it.
Q2: How is 1 MHz achieved — do the 24 V inputs also reach 1 MHz?
No. The 1 MHz figure applies only to the RS-422/485 differential side: four differential inputs and four differential outputs use 5 V differential levels with steep edges and good common-mode rejection, which is what makes 1 MHz possible. The 10 digital inputs at 24 V DC and the 6 transistor outputs at 24 V DC remain limited to 100 kHz. When sizing a project, check which side each signal connects to rather than assuming 1 MHz across all channels.
Q3: What connects to the RS-422/485 differential interface? Is it a communication port?
It is differential pulse I/O, not a communication port. On the input side it accepts 5 V differential incremental encoders (A/A̅, B/B̅, Z/Z̅) for long cable runs and noisy environments; on the output side it delivers differential pulse/direction signals to servo or stepper drives with differential inputs. It does not provide RS-485 fieldbus communication — for Modbus RTU or PROFIBUS, add a CM 1241 or CM 1243-5 communication module.
Q4: Is the work memory 150 KB or 250 KB?
It depends on the firmware. This order number currently ships with firmware V4.7 and 250 KB of work memory; earlier releases (150 KB around V4.2, 125 KB before that) account for the other figures still found online. Check the firmware actually installed — readable online in TIA Portal — before quoting or sizing a program.
Q5: How many axes can it run, and does it support interpolation?
Up to 8 motion control axis resources, of which up to 4 positioning axes via the pulse/direction interface at 1 MHz; additional axes can be added over PROFINET with bus servos such as SINAMICS V90 PN. The 1217C supports PLCopen single-axis motion (absolute/relative positioning, velocity, homing) but not interpolation, cam synchronization or kinematics — those requirements call for the S7-1500T family.
Q6: Can the onboard 24 V supply feed external sensors?
Yes, within limits. The integrated 24 V encoder/load supply delivers 400 mA, enough for differential encoders and proximity switches; beyond that, use an external 24 V supply and never connect an external supply in parallel with the CPU's 24 V output. With several expansion modules, also check that 5 V backplane current stays below 1600 mA.
Q7: Can the two ports be used to separate two networks?
No. Both RJ45 ports belong to one isolated PROFINET interface on the same IP subnet — an integrated switch intended for line/daisy-chain wiring and MRP rings, not for network isolation. To separate an office network from the machine network physically, use a CPU with an independent second interface (for example the S7-1500 CPU 1516-3 PN/DP) or add an external router or firewall.
Q8: Is this model still available, and what is its lifecycle status?
Siemens currently lists it as PM300: Active Product, but the entire first-generation S7-1200 family has been announced to move to PM400 (product discontinuation) on 1 November 2026. Under Siemens' status model, new units remain orderable for about 12 months after PM400 (until the end of October 2027), then the product enters the spare-parts phase (PM410), with a spare-parts commitment of roughly 10 years counted from PM400. Because the 1217C is the only S7-1200 with 1 MHz differential I/O, any replacement must be evaluated per project (S7-1500 or the G2 platform) — stock up early for installed machines and keep a complete project backup.