6ES7215-1AG40-0XB0

The SIMATIC S7-1200 CPU 1215C (DC/DC/DC, order no. 6ES7215-1AG40-0XB0) is the best-equipped standard compact CPU in the S7-1200 range. One module integrates 14 digital inputs at 24 V DC, 10 transistor outputs at 24 V DC, 2 analog inputs at 0–10 V and 2 analog outputs at 0–20 mA, plus two RJ45 PROFINET ports with an integrated switch — a complete small control station with closed-loop capability, without a separate power supply, analog module or external switch.
Against its sibling CPU 1214C, the 1215C adds value in three places: two analog outputs that drive a variable-frequency drive's frequency reference, a proportional valve or an electro-hydraulic axis directly; two PROFINET ports that allow line and daisy-chain topologies, removing the external switch and part of the cabinet wiring; and 200 KB of work memory (firmware V4.7) for multi-recipe handling, PID loops and positioning programs.
  • 6ES7215-1AG40-0XB0

  • Siemens

Availability:
Quantity:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
kakao sharing button
snapchat sharing button
telegram sharing button
sharethis sharing button

One module, one machine. The CPU 1215C packs supply, CPU, onboard I/O and network interfaces into a 130 × 100 × 75 mm housing that clips onto a standard 35 mm DIN rail — minimal footprint, minimal wiring. Fourteen digital inputs and ten digital outputs cover the discrete signals of most standalone machines; two analog inputs take pressure, temperature or level transmitters and two analog outputs feed a drive or a control valve directly. What used to need two expansion modules now comes with the CPU, cutting hardware cost and potential failure points. A 1600 mA backplane supply leaves headroom for up to eight signal modules.

Two-port PROFINET, more freedom in wiring. Both RJ45 ports share one isolated PROFINET interface and one IP subnet through an integrated switch: several devices can be chained in a line topology without an external switch, or one port can serve the PLC/HMI level while the other serves field I/O. As an IO controller the CPU handles up to 16 PROFINET IO devices and can also act as an IO device, embedding the machine as an intelligent slave in a larger system. Firmware V4.7 provides an OPC UA server and a web server, so production data reaches MES, SCADA or cloud platforms without an extra gateway.

Technology functions built in. Six of the 14 inputs work as high-speed counters — three at 100 kHz and three at 30 kHz single-phase, or three at 80 kHz and three at 30 kHz differential — capturing encoder, flow-meter and length signals directly. Four of the ten outputs support PTO/PWM up to 100 kHz for stepper or pulse-type servo positioning, with up to 8 positioning axes via PLCopen motion control instructions. PID autotuning, a real-time clock (480 h battery-free backup), four alarm inputs plus trace and diagnostic buffers cover process control and fault analysis without additional hardware.

① Digital and analog in one unit
14 DI + 10 DO (transistor, 0.5 A) + 2 AI (0–10 V) + 2 AO (0–20 mA) — closed-loop control without an analog expansion module.

② Two-port PROFINET switch
2 × RJ45 with integrated switch for line and daisy-chain topologies, saving an external switch and cabinet wiring.

③ 200 KB work memory
200 KB work memory, 4 MB load memory and 14 KB retentive area at firmware V4.7 — room for complex logic and recipes.

④ High-speed counting and positioning
6 HSC channels up to 100 kHz, 4 PTO/PWM outputs at 100 kHz, up to 8 positioning axes for stepper or pulse servo drives.

⑤ OPC UA and web server
Firmware V4.7 includes an OPC UA server and user-defined web pages — cloud connectivity and remote diagnostics without a gateway.

⑥ Maintenance-free and expandable
Battery-free retention with 480 h clock backup; up to 8 SM + 1 SB + 3 CM with 1600 mA backplane supply.

General

Product type

CPU 1215C DC/DC/DC

Firmware version

V4.7

Engineering software

STEP 7 / TIA Portal V20 or higher

Dimensions (W × H × D)

130 × 100 × 75 mm

Net weight

approx. 500 g

Mounting / degree of protection

35 mm DIN rail or panel / IP20

Country of origin

Germany

Power supply

Rated supply voltage

24 V DC (20.4 – 28.8 V), reverse-polarity protected

Current consumption

500 mA (CPU only); max. 1500 mA with all expansion modules

Inrush current

max. 12 A at 28.8 V, I²t = 0.5 A²·s

Backplane supply (5 V DC)

max. 1600 mA for SM / CM

24 V encoder supply

L+ minus 4 V DC (min.)

Power loss

12 W typ.

Memory and performance

Work memory

200 KB integrated, not expandable

Load memory

4 MB integrated; expandable with SIMATIC Memory Card

Retentive data area

max. 14 KB (timers, counters, flags)

Bit / word / floating-point

0.08 µs | 1.7 µs | 2.3 µs

Process image

1 KB inputs / 1 KB outputs, adjustable

Data backup

Maintenance-free, battery-free

Onboard digital I/O

Digital inputs

14 × 24 V DC, sink/source selectable; 6 usable as HSC

Input threshold / delay

"0" ≤5 V (1 mA); "1" ≥15 V (2.5 mA); delay 0.2 – 12.8 ms configurable in groups of four

Digital outputs

10 × 24 V DC transistor (sourcing), 0.5 A per point; 4 usable as high-speed outputs

Output load

0.5 A resistive; lamp load max. 5 W; inductive shutdown limited to L+ (−48 V)

Output delay

"0"→"1" ≤1 µs, "1"→"0" ≤5 µs (resistive load)

Cable length (DI / DO)

Inputs 500 m shielded / 300 m unshielded; outputs 500 m shielded / 150 m unshielded

Onboard analog I/O

Analog inputs

2 × 0 – 10 V DC, 10-bit resolution, input resistance ≥100 kΩ, conversion time 625 µs per channel

Analog outputs

2 × 0 – 20 mA DC, 10-bit resolution

Analog cable length

max. 100 m, twisted and shielded

Technology functions

High-speed counters

6 total: 3 × 100 kHz + 3 × 30 kHz single-phase; 3 × 80 kHz + 3 × 30 kHz differential

Pulse outputs (PTO/PWM)

4, up to 100 kHz

Positioning axes

up to 8 (PLCopen motion control)

Closed loop / alarms

PID autotuning (up to 16 loops); 4 alarm inputs; trace and diagnostic buffer

Communication

PROFINET interface

1 interface / 2 × RJ45 ports, integrated switch, 100 Mbit/s

Roles and capacity

IO controller / IO device; up to 16 IO devices (8 of them activatable/deactivatable at runtime)

Protocols

PROFINET IO, TCP/IP, ISO-on-TCP, UDP, MODBUS TCP, SNMP, OPC UA (V4.7)

Web server

Yes, user-defined pages supported

Expansion

Signal modules (SM)

up to 8

Signal / communication board

up to 1 (SB, CB, BB combined)

Communication modules (CM)

up to 3 (e.g. CM 1241 RS-232/485, CM 1243-5 PROFIBUS DP master)

Clock and environment

Real-time clock

Yes; 480 h typical backup; deviation ≤±60 s/month at 25 °C

Ambient temperature

−20 to +60 °C horizontal; −20 to +50 °C vertical

Derating at high temperature

Above 55 °C (horizontal) / 45 °C (vertical), simultaneously active channels drop to 14 / 10; at 60 °C / 50 °C to 7 / 5

Storage temperature / humidity

−40 to +70 °C / ≤95% non-condensing

Approvals

CE, UL, cULus, FM Class I Div. 2, KC, RCM, marine approvals

Q1: Is the work memory 125 KB or 200 KB?

It depends on the firmware. This order number 6ES7215-1AG40-0XB0 currently ships with firmware V4.7 and 200 KB of work memory; earlier firmware releases (V4.4 / V4.5 and before) of the same article number had 125 KB. Many online listings still quote the old figure — always check the firmware actually installed (readable online in TIA Portal) before quoting or sizing a program.

Q2: How does the 1215C differ from the 1214C?

Discrete I/O is identical (14 DI / 10 DO / 2 AI). The differences are: (1) analog outputs — the 1215C adds 2 × 0–20 mA, the 1214C has none; (2) ports — 2 × RJ45 with integrated switch versus a single port; (3) memory — 200 KB versus 150 KB; (4) width — 130 mm versus 110 mm. Choose the 1215C when you need an analog output for a drive or proportional valve, or want a line topology without an external switch; for pure discrete standalone machines the 1214C is more economical.

Q3: Are the two ports two separate networks? Can they be used for network separation?

No. Both RJ45 ports belong to one isolated PROFINET interface on the same IP subnet — they are an integrated switch, intended for line and daisy-chain wiring, not for isolating two networks. If the office network and the machine network must be physically separated, use a CPU with genuinely independent interfaces (for example the S7-1500 CPU 1516-3 PN/DP, whose second PROFINET interface has its own IP address), or add an external router or firewall.

Q4: Can the analog outputs drive a VFD or a proportional valve directly?

Yes, with three caveats. The outputs are current type, 0–20 mA, 10-bit. For a 4–20 mA signal, scale it in TIA Portal against the engineering range (4 mA at the lower limit) rather than adding external offset hardware. If a 0–10 V signal is required, a shunt resistor in the loop converts current to voltage — but check the permissible load impedance, and keep analog cable runs within 100 m, twisted and shielded. Where accuracy beyond 10 bits (about 0.1%) is needed, use an SM 1232 analog module instead.

Q5: Is a SIMATIC Memory Card mandatory?

No. The CPU has 4 MB of integrated load memory and programs download and run without a card. The card is used for fast cloning of identical machines, firmware updates, recipes and data logging; fit one if you need to swap a CPU on site without a laptop or archive data.

Q6: Can it do motion control, and how many axes?

Yes. Four outputs provide PTO/PWM up to 100 kHz, supporting up to 8 positioning axes through PLCopen motion control instructions — suitable for stepper motors or pulse-type servo drives in point-to-point and speed control. With a PROFINET servo drive (e.g. SINAMICS V90 PN) the axes are configured as technology objects and the count depends on the TIA Portal configuration and drive capability. For interpolation, cam synchronization or kinematics, move up to the S7-1500T platform.

Q7: Can the transistor outputs switch 230 V AC loads?

No. The outputs are 24 V DC sourcing transistors and drive 24 V DC loads only; connecting a 230 V AC solenoid valve or contactor coil will destroy the output stage. Use an interposing relay for AC loads, or select the AC/DC/RLY variant (6ES7215-1BG40-0XB0). For inductive DC loads a freewheeling diode is mandatory — the switch-off transient will otherwise puncture the output transistor.

Q8: Is this model still available, and what is its lifecycle status?

Siemens lists it as PM300: Active Product, but has announced that product phase-out starts on 1 November 2026. For new projects with a long service life, evaluate migration to the new S7-1200 G2 platform now; for spares on existing machines, stock up early and keep a complete backup of the TIA Portal project, firmware version and configuration. Confirm the exact successor article number and changeover date with Siemens or your authorized distributor for your specific project.

Previous: 
Next: 

PRODUCTS

PRODUCTS

QUICK LINKS

CONTACT

+86-176-2073-4453
No. 858 Dujuan Road, Wangyue Subdistrict, Hunan Xiangjiang New Area,China
© 2026 Hunan Dream Road Electrical Technology Co., Ltd. All Rights Reserved. 
Privacy Policy            Sitemap