6ES7516-3TN00-0AB0

CPU 1516T-3 PN/DP (6ES7516-3TN00-0AB0) is the high-end technology CPU of the SIMATIC S7-1500T family, combining PLC logic, PROFINET/PROFIBUS communication and full multi-axis motion control in a single controller: one CPU runs the program and the servo synchronization together, with no separate motion controller — shorter cycle times, less hardware and a simpler architecture for high-end packaging, printing, machine tool and assembly applications.
  • 6ES7516-3TN00-0AB0

  • Siemens

Availability:
Quantity:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
kakao sharing button
snapchat sharing button
telegram sharing button
sharethis sharing button

6ES7516-3TN00-0AB0 is the CPU 1516T-3 PN/DP of the SIMATIC S7-1500T range, hardware functional status FS11, firmware V3.1. As a "T" technology CPU it extends the standard S7-1500 kernel with a motion-control firmware layer: bit instructions execute in 6 ns, work memory totals 3 MB (program) + 7.5 MB (data), and with cyclic interrupts down to 250 μs and isochronous organization blocks at 375 μs, the same scan cycle comfortably digests large logic programs and real-time multi-axis motion calculations at once.

Networking is a core strength. Interface 1 is a PROFINET IO IRT port with a 2-port switch — the real-time backbone for SINAMICS servo drives and distributed I/O, supporting isochronous real-time communication (up to 64 synchronized IO devices), MRP/MRPD ring redundancy and equidistant mode. Interface 2 is an independent Ethernet / PROFINET RT port for HMI, supervisory systems or network separation. Interface 3 is a PROFIBUS DP master (12 Mbit/s) carrying up to 125 DP slaves. The CPU integrates 2 IO controllers and 1 DP master on board, manages up to 64 distributed IO systems and 1000 distributed peripheral devices, and ships with an OPC UA server/client and an HTTPS web server for direct MES and IT integration.

Motion control is what the "T" stands for: 6400 motion control resources can be combined into speed axes, positioning axes, synchronous axes, external encoders, cams, cam tracks and measuring probes; extended motion control adds following-axis proxies and kinematics for Cartesian gantries, Delta and SCARA mechanisms, with up to 4 encoders/measuring systems supplying the actual position value and cross-PLC synchronization supported. Together with PID Compact / 3Step / Temp closed-loop control, the 6.1 cm local display, know-how / copy / integrity protection and local user management, it gives high-end OEM machinery a complete answer from control and motion to information security.

016 ns bit processing with isochronous sync

Bit 6 ns / floating-point 37 ns, cyclic interrupts down to 250 μs, IRT isochronous OBs at 375 μs — logic and multi-axis servo synchronization complete deterministically in one CPU.

02Full-spectrum motion control

6400 motion control resources combine into synchronous axes, electronic cams, flying shear, electronic gearing and measuring probes; extended kinematics covers Delta, SCARA and Cartesian gantry mechanisms.

03Three-port network architecture

X1: PROFINET IRT with 2-port switch (MRP ring); X2: independent Ethernet/RT port; X3: PROFIBUS DP master. Real-time, information and legacy DP networks stay physically separate.

043 MB + 7.5 MB of work memory

Program and data memory are allocated separately; DBs up to 7.5 MB, 8000 blocks in total. The SIMATIC Memory Card (max. 32 GB) carries data, recipes and archives with maintenance-free backup.

05Security Integrated and local diagnostics

Know-how protection, copy protection, integrity protection and local user management (UMAC); the 6.1 cm display reads IP, diagnostics and status locally, with an HTTPS web server for remote operation.

06Unified TIA Portal engineering

PLC logic, motion technology objects, SINAMICS drives and HMI are configured and commissioned in one project; OPC UA, trace functions and up to 8 engineering stations online simultaneously are supported.

Parameter

Specification

General

Order number

6ES7516-3TN00-0AB0

Product family / CPU type

SIMATIC S7-1500T, CPU 1516T-3 PN/DP (technology CPU)

Hardware status / firmware

FS11 / V3.1 (firmware updatable)

Engineering software

TIA Portal V19 (FW V3.1) or V15 (FW V2.5) and higher

Programming languages

LAD, FBD, STL, SCL, CFC, GRAPH

Display / operator controls

6.1 cm display; 6 keys + 1 mode selector switch

Memory

Work memory

3 MB for program, 7.5 MB for data (integrated)

Load memory

Plug-in SIMATIC Memory Card (mandatory), max. 32 GB

Retentive memory

Max. 512 KB; expandable to 7.5 MB with PS 60 W 24/48/60 V DC HF

Backup

Maintenance-free

Performance

Execution time

Bit 6 ns  |  word 7 ns  |  fixed-point 9 ns  |  floating-point 37 ns

Blocks / block size

8000 blocks in total (OB / FB / FC / DB) plus UDTs; DB up to 7.5 MB, FB / FC / OB up to 1 MB each

S7 counters / timers

2048 each; IEC counters / timers limited only by system memory

Bit memories / local data

16 KB; local data max. 64 KB per priority class (16 KB per block)

Isochronous mode

Distributed min. OB 6x cycle 375 μs; central 1 ms (equidistant mode supported)

Cyclic interrupt OBs

20, minimum OB 3x cycle 250 μs; 2 technology synchronous alarm OBs

I/O address area

32 KB inputs / 32 KB outputs; up to 8192 modules/submodules; 32 partial process images

Motion control (technology objects)

Motion control resources

6400 total: speed axis 40 each, positioning axis 80, synchronous axis 160, external encoder 80, cam 20, cam track 160, measuring probe 40

Extended motion control resources

192 (kinematics: Cartesian, Delta, SCARA; following-axis proxies; cam systems)

Actual position value

Up to 4 encoders / measuring systems for position control

Closed-loop control

PID Compact / PID 3Step / PID Temp

Communication

X1: PROFINET IO IRT

2 RJ45 ports + integrated switch; IO controller / IO device / Shared Device; up to 64 IRT-synchronized and 256 RT IO devices; MRP / MRPD ring (max. 50 ring members)

X2: Ethernet / PROFINET RT

1 RJ45 port, independent interface, up to 32 RT IO devices

X3: PROFIBUS DP master

RS-485, max. 12 Mbit/s; up to 125 DP slaves, 48 connections; equidistant / isochronous mode supported

System capacity

64 distributed IO systems; 1000 distributed peripheral devices in total; 2 integrated IO controllers + 1 DP master

Open communication

TCP/IP, ISO-on-TCP, UDP, DHCP/DNS/SNMP/DCP/LLDP, optional encryption; web server (HTTP/HTTPS)

OPC UA

Server + client (server requires "medium" runtime license); server up to 48 sessions and 100,000 accessible variables

Electrical

Supply voltage

24 V DC rated (permissible 19.2 – 28.8 V), reverse polarity protection

Current consumption

1.2 A rated, 1.5 A max, inrush max. 1.9 A

Power loss

Typ. 24 W; backplane bus infeed 12 W

Power failure buffering

5 ms, repetition rate ≥ 1/s

Mechanical & environmental

Dimensions (W × H × D)

15.9 × 15.8 × 8.4cm

Weight

Approx. 2.112 kg

Ambient conditions

Operating temperature per S7-1500 general specifications (horizontal 0 – 60 °C, vertical 0 – 40 °C); transport/storage −40 to +70 °C; max. installation altitude 5000 m

1How does a "T" technology CPU differ from a standard S7-1500 CPU?

T stands for Technology. A T-CPU adds a motion-control firmware layer on top of the standard S7-1500 kernel: beyond ordinary speed and positioning axes, it unlocks synchronous axes, electronic cams, following-axis proxies and kinematics (Delta / SCARA / Cartesian) with 6400 motion control resources. Note that T does not mean fail-safe — for SIL-rated integrated safety choose the TF series (e.g. 1516TF-3 PN/DP). Compared with the standard 1516-3, the T variant also offers more memory (3 + 7.5 MB vs. 1 + 5 MB) and higher speed (6 ns vs. 10 ns).

2How should the motion control capacity be understood — how many axes?

Siemens uses a resource model: this CPU provides 6400 motion control resources, where a speed axis consumes 40, a positioning axis 80, a synchronous axis 160, an external encoder 80, a cam 20, a cam track 160 and a measuring probe 40. The achievable axis count therefore depends on the object mix — roughly 80 positioning axes, up to 160 speed axes, or any mixed configuration. A further 192 extended resources cover kinematics and cam systems. Use the TIA Selection Tool to assess the impact on cycle time during configuration.

3What should each of the three interfaces be used for?

X1 (PROFINET IO IRT, 2-port switch) is the real-time backbone: SINAMICS servo drives and distributed I/O, with IRT synchronization and MRP/MRPD ring redundancy. X2 (Ethernet / PROFINET RT) serves HMI, supervisory systems or network separation. X3 (PROFIBUS DP master, 12 Mbit/s) takes over installed DP slaves and legacy drives. Real-time, information and legacy networks remain physically separate — no additional CP modules required.

4Is a SIMATIC Memory Card mandatory?

Yes — the CPU will not run without a card. The load memory is provided entirely by the SIMATIC Memory Card (max. 32 GB), holding the user program, hardware configuration, recipes and archives; copy protection can bind the program to the card or CPU serial number. When replacing a unit, insert the configured card to restore operation.

5What are the software requirements?

This hardware (FS11) ships with firmware V3.1 and is engineered with TIA Portal V19; with firmware V2.5, TIA Portal V15 or higher can be used. Firmware can be updated via the memory card. When migrating existing projects, first confirm the firmware/TIA Portal pairing, then update the hardware configuration.

6What should be considered for power supply and consumption?

24 V DC supply (19.2 – 28.8 V, reverse polarity protected), rated current 1.2 A and a typical power loss of 24 W — considerably higher than the standard 1516's 7 W, because motion-control computation is heavier. Size the system power supply (PS) for the total backplane budget including interface modules, and ensure uninterrupted power for the 5 ms buffering window.

7How can it integrate with IT systems?

A built-in OPC UA server (up to 48 sessions, 100,000 accessible variables, runtime license required) and OPC UA client connect directly to MES/SCADA. An HTTPS web server, open TCP/IP / ISO-on-TCP / UDP communication and optional encryption (TLS 1.3) cover further integration scenarios.

8What is the lifecycle status, and what should follow?

Siemens issued the phase-out announcement (PM400) for this article effective 1 October 2025, with final product cancellation (PM410) scheduled for 1 October 2026. The officially recommended migration path leads to the new-generation S7-1500 CPUs — such as CPU 1517-3 PN (6ES7517-3AQ10-0AB0) or CPU 1518-3 PN (6ES7518-3AT10-0AB0). Installed projects may continue to source this article as a spare, while new projects should be planned on the new-generation platform with a migration concept for the motion technology objects.