1772989321@qq.com    +86-17620734453
English

Product Detail

Home » Products » Siemens » PLC » 1200 series » 6ES7215-1BG40-0XB0

Product Category

Contact Us

6ES7215-1BG40-0XB0

The SIMATIC S7-1200 CPU 1215C (AC/DC/RLY, order no. 6ES7215-1BG40-0XB0) is the only compact CPU in the S7-1200 range that combines an AC supply, relay outputs, analog outputs and two PROFINET ports. It connects directly to 85–264 V AC mains without a separate 24 V power supply module, and its ten relay outputs switch both AC and DC loads at 2 A per point — enough to drive 230 V AC contactor coils, solenoid valves and indicator lamps straight from the CPU.

For machine builders and retrofit projects the benefit is immediate: one less power supply in the cabinet and one less layer of interposing relays, which simplifies wiring and spares. At the same time two 0–10 V analog inputs and two 0–20 mA analog outputs remain on board, so a VFD frequency reference, a proportional valve or a pressure/temperature transmitter connects without an analog module. Current firmware is V4.7 with 200 KB of work memory and two PROFINET ports behind an integrated switch.
  • 6ES7215-1BG40-0XB0

  • Siemens

Availability:
Quantity:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
kakao sharing button
snapchat sharing button
telegram sharing button
sharethis sharing button

control core built for AC environments. In many small machines and existing lines the control cabinet works on 230 V AC, with AC contactors, solenoid valves and lamps. The CPU 1215C AC/DC/RLY integrates an 85–264 V AC power supply into the CPU, so no 24 V power supply is needed to feed the controller, and the ten relay outputs are dry contacts that accept AC or DC loads directly — removing a layer of interposing relays and their wiring, and eliminating the risk of a transistor output being destroyed by an inductive load's switch-off transient. For converting a conventional relay cabinet to PLC control, this is the variant with the least wiring change and the smallest learning curve.

Discrete and analog signals in one unit. Fourteen 24 V DC inputs (sink/source selectable, six usable for high-speed counting), ten relay outputs, two 0–10 V analog inputs (10-bit, 625 µs conversion) and two 0–20 mA analog outputs cover almost every signal type a small machine needs: analog outputs for a drive reference or valve position, analog inputs for pressure, temperature and level transmitters. One caveat deserves attention: relay outputs are mechanical contacts with roughly 10 ms delay and an electrical life of about 100,000 operations at rated load. They suit loads that switch and hold — not high-frequency switching or pulse positioning.

Two-port PROFINET and technology functions. Both RJ45 ports share an integrated switch, supporting line and daisy-chain wiring without an external switch; as an IO controller the CPU handles up to 16 PROFINET IO devices and can also act as an IO device in a larger system. Firmware V4.7 adds an OPC UA server and a web server for direct MES/SCADA or cloud connectivity. Six high-speed counters remain available (up to 100 kHz single-phase) for encoders, flow meters and length measurement; for pulse positioning the onboard relay outputs provide no PTO — add an SB 1222 transistor signal board (up to 4 pulse/direction axes) or use a PROFINET servo drive instead.

① Mains supply, no 24 V PSU for the CPU
85–264 V AC, 47–63 Hz worldwide input — one less power supply and one less distribution level in the cabinet.

② Ten relay outputs, AC or DC
Dry contacts rated 2 A per point drive 230 V AC contactors, solenoid valves and lamps; lamp load 200 W AC / 30 W DC.

③ Analog in and out on board
2 AI (0–10 V, 10-bit, 625 µs) + 2 AO (0–20 mA, 10-bit) — VFD reference and proportional valve control without expansion.

④ Two-port PROFINET
2 × RJ45 with integrated switch for line and daisy-chain topologies; 16 IO devices; shared programming and HMI access.

⑤ 200 KB and 0.08 µs
200 KB work memory, 4 MB load memory and 14 KB retentive area at firmware V4.7; 0.08 µs bit instructions.

⑥ Low maintenance, expandable
Battery-free retention with 480 h clock backup; up to 8 SM + 1 SB + 3 CM on a 1600 mA backplane supply.

General

Product type

CPU 1215C AC/DC/RLY

Firmware version

V4.7

Engineering software

STEP 7 / TIA Portal V20 or higher

Dimensions (W × H × D)

13.6 x 11.1 x 8.5 cm

Weight

approx. 550 g

Mounting / degree of protection

35 mm DIN rail or panel / IP20

Power supply (AC)

Rated supply voltage

120 / 230 V AC

Permissible range / frequency

85 – 264 V AC | 47 – 63 Hz

Current consumption (rated)

100 mA at 120 V AC; 50 mA at 240 V AC

Current consumption (max.)

300 mA at 120 V AC; 150 mA at 240 V AC

Inrush current

max. 20 A at 264 V, I²t = 0.8 A²·s

Backplane supply (5 V DC)

max. 1600 mA for SM / CM

24 V encoder supply

20.4 – 28.8 V

Power loss

14 W typ.

Memory and performance

Work memory

200 KB integrated, not expandable

Load memory

4 MB integrated; expandable with SIMATIC Memory Card

Retentive data area

max. 14 KB (timers, counters, flags)

Bit / word / floating-point

0.08 µs | 1.7 µs | 2.3 µs

Process image

1 KB inputs / 1 KB outputs, adjustable

Data backup

Maintenance-free, battery-free

Onboard digital I/O

Digital inputs

14 × 24 V DC, sink/source selectable; 6 usable as HSC

Input threshold / delay

"0" ≤5 V (1 mA); "1" ≥15 V (2.5 mA); delay 0.2 – 12.8 ms configurable in groups of four

Digital outputs

10 × relay (dry contact), 2 A per point (resistive load)

Contact rating

2 A resistive; lamp load 30 W DC / 200 W AC

Contact life

10 million mechanical; approx. 100,000 electrical at rated load

Output delay

"0"→"1" ≤10 ms; "1"→"0" ≤10 ms (resistive load)

Short-circuit protection

None — external fuses or circuit breakers required

Cable length (DI)

500 m shielded / 300 m unshielded; 50 m for technology functions

Onboard analog I/O

Analog inputs

2 × 0 – 10 V DC, 10-bit resolution, input resistance ≥100 kΩ, conversion time 625 µs per channel

Analog outputs

2 × 0 – 20 mA DC, 10-bit resolution

Analog cable length

max. 100 m, twisted and shielded

Technology functions

High-speed counters

6 total: 3 × 100 kHz + 3 × 30 kHz single-phase; 3 × 80 kHz + 3 × 30 kHz differential

Pulse outputs (PTO/PWM)

None onboard on the relay variant; requires an SB 1222 transistor signal board

Positioning axes

up to 8 motion control axes; max. 4 via pulse/direction interface (with SB 1222)

Closed loop / alarms

PID autotuning (up to 16 loops); 4 alarm inputs; trace and diagnostic buffer

Communication

PROFINET interface

1 interface / 2 × RJ45 ports, integrated switch, 100 Mbit/s

Roles and capacity

IO controller / IO device; up to 16 IO devices (8 activatable/deactivatable at runtime)

Protocols

PROFINET IO, TCP/IP, ISO-on-TCP, UDP, MODBUS TCP, SNMP, OPC UA (V4.7)

Web server

Yes, user-defined pages supported

Expansion

Signal modules (SM)

up to 8

Signal / communication board

up to 1 (SB, CB, BB combined)

Communication modules (CM)

up to 3 (e.g. CM 1241 RS-232/485, CM 1243-5 PROFIBUS DP master)

Clock and environment

Real-time clock

Yes; 480 h typical backup; deviation ≤±60 s/month at 25 °C

Ambient temperature

−20 to +60 °C horizontal; −20 to +50 °C vertical

Derating at high temperature

Above 55 °C (horizontal) / 45 °C (vertical), simultaneously active channels drop to 14 / 10; at 60 °C / 50 °C to 7 / 5 (non-adjacent)

Storage temperature / humidity

−40 to +70 °C / ≤95% non-condensing

Approvals

CE, UL, cULus, FM Class I Div. 2, KC, RCM, marine approvals

Q1: Can the relay outputs switch 230 V AC directly, and how is the rating calculated?

Yes — this is the main advantage over the transistor variant. Each point is a dry contact rated 2 A resistive, with a lamp load of 200 W AC / 30 W DC, so 230 V AC contactor coils, solenoid valves and lamps can be wired straight to the CPU. Three points to watch: (1) no short-circuit protection — every output circuit needs an external fuse or circuit breaker; (2) inductive loads need suppression — an RC network or varistor across an AC coil, a freewheeling diode across a DC coil, otherwise the contacts arc and weld; (3) switching frequency — contacts delay about 10 ms and are rated for roughly 100,000 electrical operations at rated load, so they suit switch-and-hold loads, not PWM or fast pulsing.

Q2: Can this variant do pulse positioning?

Not on its own. Relay contacts cannot deliver 100 kHz pulses, so no PTO/PWM is available onboard. For pulse/direction positioning add an SB 1222 transistor signal board (up to 4 pulse-type axes), or use a PROFINET servo drive such as SINAMICS V90 PN as a technology object. If the machine must position axes and cost is the priority, choose the DC/DC/DC variant (6ES7215-1AG40-0XB0) instead — it has four 100 kHz PTO outputs onboard.

Q3: Is the work memory 125 KB or 200 KB?

It depends on the firmware. This order number currently ships with firmware V4.7 and 200 KB of work memory; earlier releases (V4.5 and before) of the same article number had 125 KB. Many online listings, including some distributor pages, still quote 125 KB — always check the installed firmware (readable online in TIA Portal) before quoting or sizing a program.

Q4: With an AC supply, is a 24 V power supply still needed?

It depends on the field devices. The CPU itself runs from 85–264 V AC, so no 24 V supply is needed to power the controller. The 14 digital inputs, however, are still 24 V DC level: if you have 24 V DC sensors, encoders, or expansion modules with input circuits, a 24 V supply is still required (the CPU provides a 24 V encoder supply of 20.4–28.8 V). Also note the inrush current of up to 20 A at 264 V — when several units share a feeder, check the upstream breaker's trip characteristic and stagger power-up if necessary.

Q5: How do the three 1215C variants compare, and how does it differ from the 1214C?

The 1215C comes as DC/DC/DC (24 V supply, transistor outputs, 100 kHz pulse positioning), DC/DC/RLY (24 V supply, relay outputs) and AC/DC/RLY (this model — AC supply, relay outputs). Compared with the 1214C, the 1215C adds 2 analog outputs, a two-port PROFINET switch, 200 KB of memory and 20 mm of extra width (130 mm vs 110 mm). Decision order: need pulse positioning → 1AG40; need relays and already have 24 V in the cabinet → 1HG40; need relays and want mains direct to save a power supply → this 1BG40.

Q6: Can the two ports be used to separate two networks?

No. Both RJ45 ports belong to one isolated PROFINET interface on the same IP subnet — an integrated switch intended for line and daisy-chain wiring, not for network isolation. To separate an office network from the machine network physically, use a CPU with a genuinely independent second interface (for example the S7-1500 CPU 1516-3 PN/DP) or add an external router or firewall.

Q7: Is a SIMATIC Memory Card mandatory?

No. The CPU has 4 MB of integrated load memory and programs run without a card. The card is used for fast cloning of identical machines, firmware updates, recipes and data logging; fit one if you need to swap a CPU on site without a laptop or archive production data.

Q8: Is this model still available, and what is its lifecycle status?

Siemens currently lists it as PM300: Active Product, but the entire first-generation S7-1200 family has been announced to move to PM400 (product discontinuation) on 1 November 2026. Under Siemens' status model, new units remain orderable for about 12 months after PM400 (until the end of October 2027), then the product enters the spare-parts phase (PM410), with a spare-parts commitment of roughly 10 years counted from PM400. Practical advice: evaluate migration to the S7-1200 G2 platform for new projects, and for installed machines stock CPUs and companion modules early, keeping a complete backup of the TIA Portal project, firmware version and configuration.

Previous: 
Next: 

PRODUCTS

PRODUCTS

QUICK LINKS

CONTACT

+86-176-2073-4453
No. 858 Dujuan Road, Wangyue Subdistrict, Hunan Xiangjiang New Area,China
© 2026 Hunan Dream Road Electrical Technology Co., Ltd. All Rights Reserved. 
Privacy Policy            Sitemap