6ES7215-1BG40-0XB0
Siemens
| Availability: | |
|---|---|
| Quantity: | |
control core built for AC environments. In many small machines and existing lines the control cabinet works on 230 V AC, with AC contactors, solenoid valves and lamps. The CPU 1215C AC/DC/RLY integrates an 85–264 V AC power supply into the CPU, so no 24 V power supply is needed to feed the controller, and the ten relay outputs are dry contacts that accept AC or DC loads directly — removing a layer of interposing relays and their wiring, and eliminating the risk of a transistor output being destroyed by an inductive load's switch-off transient. For converting a conventional relay cabinet to PLC control, this is the variant with the least wiring change and the smallest learning curve.
Discrete and analog signals in one unit. Fourteen 24 V DC inputs (sink/source selectable, six usable for high-speed counting), ten relay outputs, two 0–10 V analog inputs (10-bit, 625 µs conversion) and two 0–20 mA analog outputs cover almost every signal type a small machine needs: analog outputs for a drive reference or valve position, analog inputs for pressure, temperature and level transmitters. One caveat deserves attention: relay outputs are mechanical contacts with roughly 10 ms delay and an electrical life of about 100,000 operations at rated load. They suit loads that switch and hold — not high-frequency switching or pulse positioning.
Two-port PROFINET and technology functions. Both RJ45 ports share an integrated switch, supporting line and daisy-chain wiring without an external switch; as an IO controller the CPU handles up to 16 PROFINET IO devices and can also act as an IO device in a larger system. Firmware V4.7 adds an OPC UA server and a web server for direct MES/SCADA or cloud connectivity. Six high-speed counters remain available (up to 100 kHz single-phase) for encoders, flow meters and length measurement; for pulse positioning the onboard relay outputs provide no PTO — add an SB 1222 transistor signal board (up to 4 pulse/direction axes) or use a PROFINET servo drive instead.
① Mains supply, no 24 V PSU for the CPU
85–264 V AC, 47–63 Hz worldwide input — one less power supply and one less distribution level in the cabinet.
② Ten relay outputs, AC or DC
Dry contacts rated 2 A per point drive 230 V AC contactors, solenoid valves and lamps; lamp load 200 W AC / 30 W DC.
③ Analog in and out on board
2 AI (0–10 V, 10-bit, 625 µs) + 2 AO (0–20 mA, 10-bit) — VFD reference and proportional valve control without expansion.
④ Two-port PROFINET
2 × RJ45 with integrated switch for line and daisy-chain topologies; 16 IO devices; shared programming and HMI access.
⑤ 200 KB and 0.08 µs
200 KB work memory, 4 MB load memory and 14 KB retentive area at firmware V4.7; 0.08 µs bit instructions.
⑥ Low maintenance, expandable
Battery-free retention with 480 h clock backup; up to 8 SM + 1 SB + 3 CM on a 1600 mA backplane supply.
General | |
Product type | CPU 1215C AC/DC/RLY |
Firmware version | V4.7 |
Engineering software | STEP 7 / TIA Portal V20 or higher |
Dimensions (W × H × D) | 13.6 x 11.1 x 8.5 cm |
Weight | approx. 550 g |
Mounting / degree of protection | 35 mm DIN rail or panel / IP20 |
Power supply (AC) | |
Rated supply voltage | 120 / 230 V AC |
Permissible range / frequency | 85 – 264 V AC | 47 – 63 Hz |
Current consumption (rated) | 100 mA at 120 V AC; 50 mA at 240 V AC |
Current consumption (max.) | 300 mA at 120 V AC; 150 mA at 240 V AC |
Inrush current | max. 20 A at 264 V, I²t = 0.8 A²·s |
Backplane supply (5 V DC) | max. 1600 mA for SM / CM |
24 V encoder supply | 20.4 – 28.8 V |
Power loss | 14 W typ. |
Memory and performance | |
Work memory | 200 KB integrated, not expandable |
Load memory | 4 MB integrated; expandable with SIMATIC Memory Card |
Retentive data area | max. 14 KB (timers, counters, flags) |
Bit / word / floating-point | 0.08 µs | 1.7 µs | 2.3 µs |
Process image | 1 KB inputs / 1 KB outputs, adjustable |
Data backup | Maintenance-free, battery-free |
Onboard digital I/O | |
Digital inputs | 14 × 24 V DC, sink/source selectable; 6 usable as HSC |
Input threshold / delay | "0" ≤5 V (1 mA); "1" ≥15 V (2.5 mA); delay 0.2 – 12.8 ms configurable in groups of four |
Digital outputs | 10 × relay (dry contact), 2 A per point (resistive load) |
Contact rating | 2 A resistive; lamp load 30 W DC / 200 W AC |
Contact life | 10 million mechanical; approx. 100,000 electrical at rated load |
Output delay | "0"→"1" ≤10 ms; "1"→"0" ≤10 ms (resistive load) |
Short-circuit protection | None — external fuses or circuit breakers required |
Cable length (DI) | 500 m shielded / 300 m unshielded; 50 m for technology functions |
Onboard analog I/O | |
Analog inputs | 2 × 0 – 10 V DC, 10-bit resolution, input resistance ≥100 kΩ, conversion time 625 µs per channel |
Analog outputs | 2 × 0 – 20 mA DC, 10-bit resolution |
Analog cable length | max. 100 m, twisted and shielded |
Technology functions | |
High-speed counters | 6 total: 3 × 100 kHz + 3 × 30 kHz single-phase; 3 × 80 kHz + 3 × 30 kHz differential |
Pulse outputs (PTO/PWM) | None onboard on the relay variant; requires an SB 1222 transistor signal board |
Positioning axes | up to 8 motion control axes; max. 4 via pulse/direction interface (with SB 1222) |
Closed loop / alarms | PID autotuning (up to 16 loops); 4 alarm inputs; trace and diagnostic buffer |
Communication | |
PROFINET interface | 1 interface / 2 × RJ45 ports, integrated switch, 100 Mbit/s |
Roles and capacity | IO controller / IO device; up to 16 IO devices (8 activatable/deactivatable at runtime) |
Protocols | PROFINET IO, TCP/IP, ISO-on-TCP, UDP, MODBUS TCP, SNMP, OPC UA (V4.7) |
Web server | Yes, user-defined pages supported |
Expansion | |
Signal modules (SM) | up to 8 |
Signal / communication board | up to 1 (SB, CB, BB combined) |
Communication modules (CM) | up to 3 (e.g. CM 1241 RS-232/485, CM 1243-5 PROFIBUS DP master) |
Clock and environment | |
Real-time clock | Yes; 480 h typical backup; deviation ≤±60 s/month at 25 °C |
Ambient temperature | −20 to +60 °C horizontal; −20 to +50 °C vertical |
Derating at high temperature | Above 55 °C (horizontal) / 45 °C (vertical), simultaneously active channels drop to 14 / 10; at 60 °C / 50 °C to 7 / 5 (non-adjacent) |
Storage temperature / humidity | −40 to +70 °C / ≤95% non-condensing |
Approvals | CE, UL, cULus, FM Class I Div. 2, KC, RCM, marine approvals |
Q1: Can the relay outputs switch 230 V AC directly, and how is the rating calculated?
Yes — this is the main advantage over the transistor variant. Each point is a dry contact rated 2 A resistive, with a lamp load of 200 W AC / 30 W DC, so 230 V AC contactor coils, solenoid valves and lamps can be wired straight to the CPU. Three points to watch: (1) no short-circuit protection — every output circuit needs an external fuse or circuit breaker; (2) inductive loads need suppression — an RC network or varistor across an AC coil, a freewheeling diode across a DC coil, otherwise the contacts arc and weld; (3) switching frequency — contacts delay about 10 ms and are rated for roughly 100,000 electrical operations at rated load, so they suit switch-and-hold loads, not PWM or fast pulsing.
Q2: Can this variant do pulse positioning?
Not on its own. Relay contacts cannot deliver 100 kHz pulses, so no PTO/PWM is available onboard. For pulse/direction positioning add an SB 1222 transistor signal board (up to 4 pulse-type axes), or use a PROFINET servo drive such as SINAMICS V90 PN as a technology object. If the machine must position axes and cost is the priority, choose the DC/DC/DC variant (6ES7215-1AG40-0XB0) instead — it has four 100 kHz PTO outputs onboard.
Q3: Is the work memory 125 KB or 200 KB?
It depends on the firmware. This order number currently ships with firmware V4.7 and 200 KB of work memory; earlier releases (V4.5 and before) of the same article number had 125 KB. Many online listings, including some distributor pages, still quote 125 KB — always check the installed firmware (readable online in TIA Portal) before quoting or sizing a program.
Q4: With an AC supply, is a 24 V power supply still needed?
It depends on the field devices. The CPU itself runs from 85–264 V AC, so no 24 V supply is needed to power the controller. The 14 digital inputs, however, are still 24 V DC level: if you have 24 V DC sensors, encoders, or expansion modules with input circuits, a 24 V supply is still required (the CPU provides a 24 V encoder supply of 20.4–28.8 V). Also note the inrush current of up to 20 A at 264 V — when several units share a feeder, check the upstream breaker's trip characteristic and stagger power-up if necessary.
Q5: How do the three 1215C variants compare, and how does it differ from the 1214C?
The 1215C comes as DC/DC/DC (24 V supply, transistor outputs, 100 kHz pulse positioning), DC/DC/RLY (24 V supply, relay outputs) and AC/DC/RLY (this model — AC supply, relay outputs). Compared with the 1214C, the 1215C adds 2 analog outputs, a two-port PROFINET switch, 200 KB of memory and 20 mm of extra width (130 mm vs 110 mm). Decision order: need pulse positioning → 1AG40; need relays and already have 24 V in the cabinet → 1HG40; need relays and want mains direct to save a power supply → this 1BG40.
Q6: Can the two ports be used to separate two networks?
No. Both RJ45 ports belong to one isolated PROFINET interface on the same IP subnet — an integrated switch intended for line and daisy-chain wiring, not for network isolation. To separate an office network from the machine network physically, use a CPU with a genuinely independent second interface (for example the S7-1500 CPU 1516-3 PN/DP) or add an external router or firewall.
Q7: Is a SIMATIC Memory Card mandatory?
No. The CPU has 4 MB of integrated load memory and programs run without a card. The card is used for fast cloning of identical machines, firmware updates, recipes and data logging; fit one if you need to swap a CPU on site without a laptop or archive production data.
Q8: Is this model still available, and what is its lifecycle status?
Siemens currently lists it as PM300: Active Product, but the entire first-generation S7-1200 family has been announced to move to PM400 (product discontinuation) on 1 November 2026. Under Siemens' status model, new units remain orderable for about 12 months after PM400 (until the end of October 2027), then the product enters the spare-parts phase (PM410), with a spare-parts commitment of roughly 10 years counted from PM400. Practical advice: evaluate migration to the S7-1200 G2 platform for new projects, and for installed machines stock CPUs and companion modules early, keeping a complete backup of the TIA Portal project, firmware version and configuration.