6ES7513-1AL02-0AB0
Siemens
| Availability: | |
|---|---|
| Quantity: | |
One Ethernet interface, two ports, real-time capable. The 1513-1 PN has a single PROFINET interface split into two RJ45 ports through an integrated switch. That arrangement is what makes line and ring topologies practical: devices are daisy-chained port to port, and with MRP a broken cable is redirected within a typical 200 ms — with MRPD under IRT the ring is even hitless. PROFINET IRT with isochronous mode allows a 250 µs send cycle, and up to 128 IO devices can be operated on the interface, 64 of them with IRT. For machines with a dozen remote IO stations, servo drives and a panel, this is comfortably more than the application needs.
Memory and speed sized for real machines. 300 KB of program memory and 1.5 MB of data memory hold a mid-sized application with several hundred blocks — up to 4 000 elements in total, with 100 cyclic OBs, 20 time-of-day and 20 delay interrupts, 50 process interrupts and two isochronous OBs. Block sizes can reach 300 KB for OB, FB and FC, and 1.5 MB for a data block (64 KB when absolutely addressed). At 40 ns per bit instruction, 48 ns per word, 64 ns for fixed-point and 256 ns for floating-point arithmetic, the CPU handles closed-loop control and data handling in the same cycle without splitting the program. Retentive memory is 128 KB, of which 88 KB is available for retentive bit memory, timers, counters, DBs and technology data.
Motion, diagnostics and IT integration. Motion control is integrated with 800 resources — enough for roughly five positioning axes at a 4 ms cycle or ten axes at 8 ms, plus external encoders, output cams and cam tracks. The PID_Compact, PID_3Step and PID-Temp blocks with integrated optimization cover the temperature and pressure loops that usually sit alongside the motion axes. Diagnostics go beyond a fault LED: the display shows the module and channel, the diagnostic buffer is readable in TIA Portal and over the web server, and the CPU supports OPC UA (server with 32 sessions and a client with up to four connections) as well as HTTPS — subject to the OPC UA runtime licence. That is what allows the controller to feed MES or cloud systems directly, without an additional gateway.
① 300 KB / 1.5 MB work memory
Program and data memory separated; 4 000 blocks, 1.5 MB data blocks, 128 KB retentive area (88 KB usable).
② 40 ns bit performance
40 ns bit, 48 ns word, 64 ns fixed-point, 256 ns floating-point — closed-loop and logic in one cycle.
③ PROFINET IRT, 2-port switch
1 interface, 2 RJ45 ports, 250 µs IRT send cycle, isochronous mode, 128 IO devices (64 with IRT).
④ MRP / MRPD redundancy
Ring redundancy with a typical 200 ms switchover, hitless with MRPD under IRT — no external switches needed.
⑤ 800 motion control resources
About 5 positioning axes at 4 ms or 10 at 8 ms, plus external encoders, output cams and cam tracks.
⑥ Display, OPC UA, web server
3.45 cm display with 8 keys for local diagnostics; OPC UA server/client and HTTPS web server (licence required).
General | |
Product type | CPU 1513-1 PN (standard CPU, not fail-safe) |
Hardware version | FS03 |
Firmware version | V2.9 |
Engineering software | TIA Portal V17 (FW V2.9); V15 for FW V2.5 |
Dimensions (W × H × D) | 35 × 147 × 129 mm |
Weight | approx. 405 g |
Mounting / degree of protection | S7-1500 profile rail / IP20 |
Memory | |
Work memory, program | 300 KB |
Work memory, data | 1.5 MB |
Load memory | SIMATIC Memory Card, max. 32 GB (required) |
Retentive data area | 128 KB max., of which 88 KB usable |
Bit memory (M) | 16 KB max. |
Data block size | 1.5 MB (64 KB when absolutely addressed) |
OB / FB / FC size | 300 KB each |
Performance | |
Bit / word operations | 40 ns / 48 ns |
Fixed-point / floating-point | 64 ns / 256 ns |
Elements (OB, FB, FC, DB, UDT) | 4 000 total |
OBs available | 100 cyclic, 20 time-of-day, 20 delay, 50 process, 2 isochronous, 100 startup |
Nesting depth | 24 per priority class |
S7 counters / S7 timers | 2 048 / 2 048, retentivity adjustable |
IEC counters / timers | Unlimited, limited only by work memory |
Communication | |
Interfaces | 1× PROFINET (X1), 2× RJ45 with integrated switch, 100 Mbit/s |
PROFINET IO devices | 128 max. (64 with IRT); up to 512 across AS-i / PROFIBUS / PROFINET |
IRT send cycle | 250 µs / 500 µs / 1 ms / 2 ms / 4 ms |
Isochronous mode | Yes; min. OB 6× cycle 500 µs distributed, 1 ms central |
Redundancy | MRP / MRP interconnection (IEC 62439-2), MRPD; typical switchover 200 ms |
OPC UA | Server: 32 sessions, 50 000 variables. Client: 4 connections. Runtime licence "Small" required |
Web server | HTTP / HTTPS, standard and user-defined pages |
Motion control | |
Resources | 800 (speed axis 40, positioning axis 80, synchronous axis 160, encoder 80, output cam 20, cam track 160, probe 40) |
Positioning axes (typical) | 5 at 4 ms motion control cycle; 10 at 8 ms |
Closed-loop blocks | PID_Compact, PID_3Step, PID-Temp with integrated optimization |
Power, display and environment | |
Rated supply | 24 V DC (19.2 – 28.8 V), reverse polarity protected |
Current consumption | 0.7 A rated, 0.95 A max.; inrush 1.9 A |
Power loss / backplane feed | 5.7 W typ. / 10 W to the backplane bus |
Display | 3.45 cm, 8 keys and 2 mode buttons; switches off above 50 °C (horizontal) / 40 °C (vertical) |
Ambient temperature | −25 to +60 °C horizontal / −25 to +40 °C vertical |
Storage and transport | −40 to +70 °C; installation altitude up to 5 000 m |
Q1. Is the SIMATIC Memory Card included?
No — and the CPU will not run without one. The 1513-1 PN has no integral load memory: the program, configuration and retentive data live on the card, which can be up to 32 GB. Order the card with the CPU, and keep a programmed spare card on the shelf — it is the fastest way to bring a machine back after a controller failure.
Q2. What is the difference to the current CPU 1513-1 PN, 6ES7513-1AM03-0AB0?
The AM03 is the successor and roughly doubles the resources: 600 KB program and 2.5 MB data memory instead of 300 KB / 1.5 MB, with faster bit performance. It is a compatible replacement — Siemens states the STEP 7 project does not need to be changed when a 1AL02 is replaced by a 1AM03, and the new CPU can also be configured under the old article number in older TIA Portal versions, in which case it behaves as the predecessor (firmware V2.9). For a new machine, specify the AM03; keep the 1AL02 for the installed base.
Q3. Does it have a PROFIBUS DP interface?
No. The 1513-1 PN has PROFINET only — the "-1 PN" in the name identifies a single PROFINET interface, and there is no integrated DP port (that is the "PN/DP" variant, e.g. CPU 1516-3 PN/DP). If a machine still has DP drives or DP remote IO, add a CM 1542-5 communication module, or plan the migration to PROFINET.
Q4. Can it be used for safety functions?
No. This is a standard CPU without integrated fail-safe functionality. Safety applications — e-stop, guard doors, safe speed — require the F-version CPU 1513F-1 PN and the corresponding F-DI / F-DO modules, engineered with the safety program in TIA Portal. Standard and F programs can run in the same F-CPU, but not in this one.
Q5. How many axes can it actually run?
Siemens quotes 800 motion control resources, and the number of axes depends on the mix of objects. As a planning figure: about five positioning axes at a 4 ms motion control cycle, or ten at 8 ms. A synchronous axis costs 160 resources, a positioning axis 80, a speed axis 40, so a gearing application uses resources faster than a simple positioning task. Also leave headroom in the cycle for the technology objects to be calculated alongside the user program.
Q6. Do the two PROFINET ports give me two separate networks?
No. Both ports belong to the same interface, the same IP address and the same subnet — the second port is an internal switch, intended for daisy-chain and ring wiring. To separate the machine network from the plant network, use a CPU with a second independent interface (such as the 1516-3 PN/DP) or a managed switch / router in front of the CPU.
Q7. Is a licence needed for OPC UA?
Yes. OPC UA server and client functionality requires the OPC UA runtime licence ("Small") on the CPU. Without it, the OPC UA server cannot be activated, although the web server and S7 communication work regardless. Plan the licence with the project — retrofitting it later means a separate order and a download window.
Q8. What is its lifecycle status?
This article is at the end of its sales life. Siemens records delivery release on 29 March 2018, the announcement of product phase-out on 1 May 2024, and product cancellation on 1 April 2025. It is now supplied as a spare part only, subject to stock. The designated successor is 6ES7513-1AM03-0AB0. For existing machines, stock spares or plan the replacement; for new projects, specify the successor.