6ES7515-2AM01-0AB0
Siemens
| Availability: | |
|---|---|
| Quantity: | |
Two PROFINET interfaces, doing two different jobs. Interface X1 is the machine network: two RJ45 ports behind an integrated switch, PROFINET IRT with isochronous mode, a 250 µs send cycle and up to 256 IO devices, 64 of them with IRT. Interface X2 is a single port with no switch, PROFINET RT only, no IRT and no isochronous mode, and its own IP address — 32 IO devices can be attached there. In practice X2 carries the HMI, the line-level SCADA connection or a link to the plant network, while X1 keeps the drives, remote IO and safety-related peripherals in a closed, deterministic segment. That separation is the main engineering reason to specify a 1515-2 PN rather than a CPU with a single switched interface: it removes the need for an external router or a second network module when the machine has to be connected upward.
Memory, speed and program structure. 500 KB of program memory and 3 MB of data memory hold a large application — up to 8 000 elements in total (OB, FB, FC, DB and UDT), with 100 cyclic OBs, 20 time-of-day and 20 delay interrupts, 20 cyclic interrupts down to 500 µs, 50 process interrupts, two isochronous OBs and 100 startup OBs. Blocks can reach 500 KB for OB, FB and FC, and 3 MB for a data block (64 KB when absolutely addressed). At 30 ns per bit instruction, 36 ns per word, 48 ns for fixed-point and 192 ns for floating-point arithmetic, closed-loop control, motion and data handling can share one cycle without being split across controllers. Retentive memory is 512 KB, of which 472 KB is usable for retentive bit memory, timers, counters, DBs and technology data; with the PS 60 W 24/48/60 V DC HF power supply the retentive area can be extended to 3 MB.
Motion, diagnostics and IT integration. Motion control is integrated with 2 400 resources — Siemens quotes roughly seven positioning axes at a 4 ms motion control cycle, or fourteen at 8 ms, plus external encoders, output cams, cam tracks and probes. PID_Compact, PID_3Step and PID-Temp cover the temperature, pressure and flow loops that usually sit beside the axes. Diagnostics reach beyond the fault LED: the display names the module and channel, the 3 200-entry diagnostic buffer is readable in TIA Portal and through the web server, and four traces can record signals inside the controller. OPC UA server (48 sessions, up to 100 000 accessible variables) and client (10 connections), HTTPS and Modbus TCP make the CPU a data source for MES and higher-level systems without an additional gateway — subject to the OPC UA runtime licence "Medium".
① Two independent PROFINET interfaces
X1: IRT, 2-port switch, 256 IO devices (64 IRT). X2: separate IP and subnet, RT only, 32 IO devices — machine and plant networks without an external router.
② 500 KB / 3 MB work memory
8 000 elements, 500 KB blocks, 3 MB data blocks, 512 KB retentive area (472 KB usable), extendable to 3 MB with the HF power supply.
③ 30 ns bit performance
30 ns bit, 36 ns word, 48 ns fixed-point, 192 ns floating-point — logic, closed-loop control and motion in a single cycle.
④ 2 400 motion control resources
About 7 positioning axes at 4 ms or 14 at 8 ms; synchronous axes, external encoders, output cams, cam tracks and probes included.
⑤ Ring redundancy and isochronous mode
MRP / MRP interconnection / MRPD with a typical 200 ms switchover, up to 50 nodes per ring; isochronous OBs from 500 µs.
⑥ Display, OPC UA, web server
6.1 cm display with 6 keys for local diagnostics; OPC UA server and client, HTTPS web server, Modbus TCP (OPC UA licence "Medium" required).
General | |
Product type | CPU 1515-2 PN (standard CPU, not fail-safe) |
Hardware version | FS03 |
Firmware version | V2.9 |
Engineering software | TIA Portal V17 (FW V2.9); V13 or higher for FW V1.5 and above |
Dimensions (W × H × D) | 70 × 147 × 129 mm |
Weight | approx. 830 g |
Mounting / degree of protection | S7-1500 profile rail / IP20 |
Memory | |
Work memory, program | 500 KB |
Work memory, data | 3 MB |
Load memory | SIMATIC Memory Card, max. 32 GB (required, 1 slot) |
Retentive data area | 512 KB max., of which 472 KB usable; extendable to 3 MB with PS 60 W 24/48/60 V DC HF |
Bit memory (M) | 16 KB max.; 8 clock memory bits |
Data block size | 3 MB (64 KB when absolutely addressed) |
OB / FB / FC size | 500 KB each |
Performance | |
Bit / word operations | 30 ns / 36 ns |
Fixed-point / floating-point | 48 ns / 192 ns |
Elements (OB, FB, FC, DB, UDT) | 8 000 total |
OBs available | 100 cyclic, 20 time-of-day, 20 delay, 20 cyclic (min. 500 µs), 50 process, 2 isochronous, 100 startup |
Nesting depth | 24 per priority class |
S7 counters / S7 timers | 2 048 / 2 048, retentivity adjustable |
IEC counters / timers | Unlimited, limited only by work memory |
I/O address area | 32 KB inputs / 32 KB outputs in the process image |
Communication | |
Interface X1 | PROFINET IRT, 2× RJ45 with integrated switch, 100 Mbit/s |
Interface X2 | PROFINET RT, 1× RJ45, no switch, no IRT, no isochronous mode |
IO devices | 256 on X1 (64 with IRT) + 32 on X2; up to 1 000 across AS-i / PROFIBUS / PROFINET |
IRT send cycle | 250 µs / 500 µs / 1 ms / 2 ms / 4 ms (odd cycles in 125 µs steps) |
Isochronous mode | Yes on X1; min. OB 6× cycle 500 µs distributed, 1 ms central |
Redundancy | MRP / MRP interconnection / MRPD, typical switchover 200 ms, max. 50 nodes per ring |
Connections | 192 max. (108 on the integrated interface, 10 reserved for ES / HMI / web); 16 S7 routing paths |
OPC UA | Server: 48 sessions, 100 000 variables. Client: 10 connections. Runtime licence "Medium" required |
Web server / protocols | HTTP and HTTPS, standard and user pages; Modbus TCP; NTP time synchronisation |
Motion control | |
Resources | 2 400 (speed axis 40, positioning axis 80, synchronous axis 160, encoder 80, output cam 20, cam track 160, probe 40) |
Positioning axes (typical) | 7 at 4 ms motion control cycle; 14 at 8 ms |
Closed-loop blocks | PID_Compact, PID_3Step, PID-Temp with integrated optimization |
Power, display and environment | |
Rated supply | 24 V DC (19.2 – 28.8 V), reverse polarity protected; 5 ms power-fail buffering |
Current consumption | 0.8 A rated; inrush 2.4 A max. (I²t 0.02 A²s) |
Power loss / backplane | 6.3 W typ.; 12 W fed to the backplane bus, 6.2 W drawn from it |
Display | 6.1 cm, 6 keys and 1 mode selector; switches off above 50 °C horizontal / 40 °C vertical |
Ambient temperature | 0 to +60 °C horizontal / 0 to +40 °C vertical |
Storage and transport | −40 to +70 °C; installation altitude up to 5 000 m (restrictions above 2 000 m) |
Rack / expansion | Max. 32 modules per rack (CPU + 31), single row; 8 192 IO modules addressable |
Q1. Is the SIMATIC Memory Card included, and is it mandatory?
It is not included and it is mandatory. The 1515-2 PN has no integral load memory — program, configuration, recipes and retentive data live on the card, which can be up to 32 GB. Order the card together with the CPU. For the installed base, keep a programmed spare card on site: after a controller failure it is the fastest route back to production, because the card carries the complete program and hardware configuration.
Q2. X1 and X2 — what is the real difference?
X1 is the machine network: two RJ45 ports behind an integrated switch, PROFINET IRT with isochronous mode, 256 IO devices, 64 of them IRT-capable. X2 is a single port without a switch, PROFINET RT only — no IRT, no isochronous mode — with its own IP address and subnet, and room for 32 IO devices. So X2 can carry an HMI, a line-level SCADA link or the connection to the plant backbone while X1 keeps drives and remote IO in a closed, deterministic segment. Do not expect IRT performance on X2: drives that need isochronous synchronism belong on X1.
Q3. How does it differ from the 1513-1 PN and the 1516-3 PN/DP?
Against the 1513-1 PN: the 1515-2 PN has 500 KB / 3 MB instead of 300 KB / 1.5 MB, 30 ns instead of 40 ns, 2 400 instead of 800 motion resources, 192 instead of 128 connections — and, above all, a genuinely independent second interface. Against the 1516-3 PN/DP: the 1515-2 PN has two PROFINET interfaces but no PROFIBUS DP port, and less memory (500 KB / 3 MB versus 1 MB / 5 MB). If the machine still has DP drives or DP remote IO, the 1516-3 PN/DP is the shorter route; if everything is PROFINET, the 1515-2 PN covers the same network separation for less money.
Q4. Can it run safety functions?
No. This is a standard CPU with no integrated fail-safe functionality, and PROFIsafe is not supported. Safety applications — e-stop, guard doors, safe speed, safe torque off — require the F-version CPU 1515F-2 PN with the corresponding F-DI / F-DO modules, engineered with the safety program in TIA Portal. Standard and safety programs can run in the same F-CPU, but not in this one.
Q5. How many axes can it actually run?
Siemens quotes 2 400 motion control resources, and the axis count depends on the mix of technology objects: a positioning axis costs 80 resources, a synchronous axis 160, a speed axis 40, an external encoder 80, an output cam 20, a cam track 160. As planning figures, about seven positioning axes at a 4 ms motion control cycle, or fourteen at 8 ms. Gearing and camming applications consume resources faster than simple positioning. Leave cycle headroom as well — technology objects are calculated alongside the user program, and heavy cam work lengthens the cycle.
Q6. What licence does OPC UA need?
The "Medium" runtime licence. Note that this is one step above the 1513-1 PN, which runs with the "Small" licence — a detail that is easy to miss when a project is moved from one CPU to another. Without the licence the OPC UA server cannot be activated; the web server, S7 communication and Modbus TCP work regardless. Order the licence with the project, since retrofitting means a separate order and a download window.
Q7. What is the lifecycle status, and what replaces it?
This article is at the end of its life and is supplied as a spare part only. Siemens records PM410: product cancellation, effective 2 June 2020. The direct successor was 6ES7515-2AM02-0AB0, itself cancelled on 1 October 2024; the current successor for new projects is 6ES7515-2AN03-0AB0 — same CPU 1515-2 PN, but 1 MB program and 4.5 MB data memory, 6 ns bit performance, firmware V4.1 and TIA Portal V21. Availability and lead time for the spare-part article should be confirmed with Siemens or an authorized distributor before quoting.
Q8. What has to be checked when replacing a 2AM01 with the 2AN03?
Mechanically and functionally the AN03 drops into the same slot, but plan the software side: firmware V4.1 requires TIA Portal V21 (older TIA versions can address the new CPU as a 2AM02, in which case it behaves as the predecessor), the memory is larger so block limits change, and the hardware configuration must be compiled and downloaded again. Check that the memory card is compatible and large enough, re-verify PROFINET device names and IP addresses after download, and confirm that any OPC UA or web-server settings survived the migration. For a machine that must keep running, keep the old CPU as an immediate spare rather than re-engineering the program under production pressure.