1769-OW16
AB
| Availability: | |
|---|---|
| Quantity: | |
The 1769-OW16 receives commands from a CompactLogix or MicroLogix 1500 controller and energizes relay coils to actuate normally open contacts, providing galvanic isolation between the control circuit and field loads. Each output channel features an independent yellow status LED for on-site diagnostics, and a removable terminal block simplifies wiring and maintenance. With contact ratings of 250V AC / 2A and 30V DC / 2A (resistive) and an operating range of 5~265V AC / 5~125V DC, a single module covers switching needs from small signals to power circuits.
● 16 relay outputs: two isolated groups (2 groups × 8 points) support mixed AC/DC wiring
● Wide-voltage contacts: 5~265V AC / 5~125V DC for a variety of field loads
● Per-channel LED indicators: output status at a glance, faster troubleshooting
● Electrical isolation: 1836V AC (1 s) group-to-group isolation protects the control system
● Removable terminal block: fast wiring and solder-free maintenance
● Modular mounting: standard 1769 Compact I/O form factor, mounts within 8 modules of the power supply with no added chassis cost
● Industrial-grade design: 0~60°C operating temperature, UL 94 V-0 flame-retardant housing
Item | Specification |
Catalog Number | 1769-OW16 |
Output Points | 16 relay outputs (normally open, Form A), 2 isolated groups × 8 points |
Output Voltage Range | 5~265V AC / 5~125V DC |
Contact Rating | 250V AC 2A, 30V DC 2A (resistive) |
Switching Time | approx. 10ms ON / 10ms OFF |
Backplane Current / Power | 205mA @5.1V DC; 180mA @24V DC / 4.75W max |
Isolation Voltage | 1836V AC @1s / 2596V DC @1s (group to group) |
Operating / Storage Temp. | 0~60°C / -40~85°C |
Wiring | 22~14 AWG copper wire, terminal torque 0.68 N·m |
Mounting Position | Within 8 modules of the system power supply |
Certifications | UL, CE, UKCA and other industry certifications |
Q1: Which controllers is the 1769-OW16 compatible with? It works with the 1769 Compact I/O platform of CompactLogix and MicroLogix 1500 controllers.
Q2: Can AC and DC loads be mixed on one module? Yes. The module has two isolated groups, so AC and DC loads can be connected in different groups; do not mix voltage types within the same group.
Q3: What is the load capacity of each output point? Each normally open contact is rated 250V AC / 2A or 30V DC / 2A (resistive). Surge suppression is recommended for inductive loads.
Q4: How is the module installed? It mounts as a standard 1769 I/O module in a CompactLogix system, within 8 modules of the power supply (e.g. 1769-PA2/PB2).
Q5: Is a conformally coated version available? Yes. For harsh environments (corrosive gases), choose the conformally coated 1769-OW16K variant.