8BVP0440HW00.000-1
Siemens
| Availability: | |
|---|---|
| Quantity: | |
Featuring a wide input voltage range (3×220 to 3×480 VAC ±10%) and compatibility with TT / TN-S / TN-C-S networks, the module integrates PFC power factor correction and regenerative capability to stabilize the DC bus and recover braking energy. It provides 2 slots for ACOPOSmulti plug-in modules (expandable with encoder interfaces, digital/analog I/O and other options), an integrated temperature sensor connection, 24 VDC auxiliary outputs and a fan power connection, and supports dynamic node allocation (DNA). Certifications including CE, UKCA, UL/cULus and KC enable safe deployment worldwide, supporting both new machine integration and spare-part replacement in legacy equipment.
Wide Input Voltage Range3×220 ~ 3×480 VAC ±10%, 50/60 Hz — suitable for grids worldwide
Regenerative CapabilityRegenerative operation plus PFC power factor correction for energy efficiency
2 Plug-in Module SlotsExpandable with encoder interfaces, I/O or brake chopper options
High Power Output30 kW continuous (supply and regeneration), 60 kW peak power
Integrated Auxiliary Power2 × 24 VDC outputs (250 mA electronic fuse protection) + 4.2 A fan supply
Global CertificationsCE / UKCA / UL cULus E225616 / KC
Model | 8BVP0440HW00.000-1 (ACOPOSmulti power supply module, 44 A, HV, wall mounting) |
|---|---|
Input voltage / frequency | 3×220 ~ 3×480 VAC ±10%, 50/60 Hz ±4% (TT, TN-S, TN-C-S) |
Installed load | Max. 31.1 kW |
Output power | Continuous power (supply and regeneration) 30 kW; peak power 60 kW |
DC bus voltage | Nominal 750 VDC, DC bus capacitance 825 µF |
Max. chargeable DC bus capacitance | 230 VAC: 17.4 mF | 400 VAC: 5.8 mF | 480 VAC: 4 mF |
Switching frequency | Nominal 5 kHz (selectable 5 / 10 kHz) |
Inrush current | Max. 67 A at 400 VAC, switch-on interval >300 s |
Line fuse | Max. 132 A (gG fuses per IEC 60269-1 or Class CC/J/T); max. 110 A circuit breaker |
Plug-in module slots | 2 (ACOPOSmulti plug-in modules) |
Auxiliary outputs | 2 × 24 VDC ±6% (250 mA electronic fuse, automatic reset); fan supply 24 VDC / 4.2 A |
Mounting / orientation | Wall mounting; vertically hanging or horizontal, face up |
Dimensions / weight | 106.5 mm (W) × 317 mm (H) × 263 mm (D); approx. 5.5 kg |
Protection | IP20 (EN 60529), overvoltage category III, pollution degree 2 |
Ambient temperature | Operation 5 ~ 40 °C (max. 55 °C); storage -25 ~ 55 °C; transport -25 ~ 70 °C |
Humidity / altitude | Operation 5 ~ 85% RH; nominal altitude 0 ~ 500 m (up to 4000 m with derating of 3 kW per 1000 m above 500 m) |
Standby losses | 10.8 W |
Certifications | CE, UKCA, UL cULus E225616 (power conversion equipment), KC |
Mandatory accessories | Terminal block set 8BZVP044000.000-1A |
Q1: What role does the 8BVP0440HW00.000-1 play in the drive system?
It is the central power supply module of the ACOPOSmulti drive system. It rectifies three-phase mains power into a 750 VDC DC bus that powers the inverter modules installed on the same backplane, and manages regeneration, power factor correction and DC bus charging.
Q2: What supply networks is the module compatible with?
It accepts three-phase mains from 3×220 to 3×480 VAC (±10%) at 50/60 Hz, with TT, TN-S and TN-C-S network configurations. The wide input range makes it suitable for most industrial power grids worldwide.
Q3: What are the continuous and peak power ratings?
Continuous DC bus power (in both supply and regeneration directions) is 30 kW, with short-term peak power up to 60 kW and a maximum installed load of 31.1 kW. Derating applies when the input voltage is below 3×400 VAC, the DC bus voltage is below 750 VDC, the switching frequency is set to 10 kHz, or at altitudes above 500 m (3 kW per 1000 m).
Q4: How does it differ from the 22 A version (8BVP0220HW00.000-1)?
Both share the same dimensions (106.5 × 317 × 263 mm) and support regeneration and PFC. This 44 A version delivers 30 kW continuous / 60 kW peak power (vs. 15 kW / 37.5 kW), a higher installed load (31.1 kW), larger line fuses (132 A gG) and a larger DC bus capacitance (825 µF), making it suitable for systems with more axes and higher power demand.
Q5: How is the module mounted, and which orientations are allowed?
It is wall-mounted and supports vertically hanging or horizontal, face-up orientation; standing horizontally on its side is not permitted. The module measures 106.5 mm in width, 317 mm in height and 263 mm in depth, weighs approx. 5.5 kg, and can be row-installed alongside ACOPOSmulti inverter modules in the control cabinet.
Q6: Does the module support energy regeneration?
Yes. The module is regenerative-capable with 30 kW continuous power in both supply and regeneration directions. It feeds braking energy from the servo motors back into the mains and includes built-in PFC power factor correction to reduce energy consumption and harmonic distortion.
Q7: Which accessories are required for installation?
The mandatory terminal block set is 8BZVP044000.000-1A (including 8TB2106.2010-00, 8TB2108.2010-00, 8TB2104.204A-00 and 8TB4104.202L-10). Terminals accept flexible fine-stranded wires from 0.5 to 16 mm² (with wire-end sleeves); the shield connection accommodates cables from 23 to 35 mm. Optional accessories include the encoder buffering battery set 8BXB000.0000-00, replacement fan module 8BXF001.0000-00, and various encoder interface plug-in modules.
Q8: Which certifications does the module have?
It is CE and UKCA certified, complies with UL cULus E225616 for power conversion equipment, and holds KC certification, meeting market access requirements in Europe, North America and Korea.