6ES7541-1AB00-0AB0
Siemens
| Availability: | |
|---|---|
| Quantity: | |
The module is powered directly from the S7-1500 backplane bus — no external supply required — and mounts on the standard 35 mm rail, with electrical isolation between the serial interface and the backplane bus (707 V DC type test). As the HF version, it supports up to 4 KB frames, an 8 KB receive buffer (255 frames) and 1200 m transmission distance (RS-422/485), plus a 32-byte performance-mode address space.
The Freeport protocol offers fully user-definable frame formats (7/8 data bits, 1/2 stop bits, various parities) to adapt to virtually any third-party serial protocol; as a Modbus RTU master it can address up to 32 slaves. For diagnostics, the module provides wire-break detection and diagnostic interrupts, with RUN/ERROR and TXD/RXD LEDs beneath the front panel for at-a-glance communication status.
● 1 × RS-422/RS-485 interface: 15-pin Sub-D socket, 4-wire full duplex (RS-422), up to 115.2 kbps
● Four protocols on board: Freeport, 3964(R), USS and Modbus RTU master/slave — no external protocol stack needed
● HF performance: max. 4 KB frames, 8 KB buffer (255 frames), 1200 m cable length, up to 32 Modbus slaves
● Backplane-powered, galvanically isolated: no external 24 V supply; interface isolated from backplane bus (707 V DC type test)
● Comprehensive diagnostics: wire-break detection, diagnostic interrupts, RUN/ERROR/TXD/RXD LED indicators
● Distributed I/O ready: usable in ET 200MP, with fast startup support for flexible configurations
● 35 mm narrow housing: mounts on the uniform S7-1500 rail, integrated in TIA Portal from V12
Item | Value |
Order number | 6ES7541-1AB00-0AB0 |
Product type designation | CM PtP RS422/485 HF |
Applicable systems | SIMATIC S7-1500 / ET 200MP |
Interface | 1 × RS-422/RS-485, 15-pin Sub-D socket |
Max. transmission rate | 115.2 kbps |
Max. cable length | 1200 m (RS-422 / RS-485) |
Integrated protocols | Freeport, 3964(R), USS, Modbus RTU master/slave |
Frame length (max.) | 4 KB; buffer 8 KB, 255 frames |
Modbus RTU master | address area 1–247 (extended 1–65535), up to 32 slaves |
Current consumption (backplane) | 33 mA (rated value) |
Backplane bus power / power loss | 0.65 W / typ. 0.6 W |
Occupied address area | 8 bytes input (32 bytes in performance mode) |
Diagnostics | wire break, diagnostic interrupt, diagnostic alarm |
Galvanic isolation | between backplane bus and interface, isolation tested 707 V DC |
Ambient temperature | 0…+60 °C horizontal / 0…+40 °C vertical installation |
Dimensions (W×H×D) | 35 × 147 × 127 mm |
Weight | approx. 220 g |
Engineering | integrated in TIA Portal from V12.0; GSD file for STEP 7 ≥V5.5 SP2 |
Q1: Is this an RS232 module?
A: No. 6ES7541-1AB00-0AB0 is the RS-422/RS-485 HF communication module (15-pin Sub-D socket). For RS232, choose the CM PtP RS232 HF of the same family (6ES7540-1AB00-0AB0).
Q2: Which serial protocols are supported? Can it connect third-party devices?
A: Freeport, 3964(R), USS and Modbus RTU master/slave are integrated. In Freeport mode the frame format (data bits, stop bits, parity) is freely definable, allowing adaptation to most third-party serial devices.
Q3: How many Modbus slaves can one module control?
A: As a Modbus RTU master it can connect up to 32 slaves, with address areas 1–247 (extendable to 65535) — ideal for small Modbus RTU networks such as multiple drives or energy meters.
Q4: What is the difference between HF and BA versions?
A: The HF version reaches 115.2 kbps (BA: 19.2 kbps), 4 KB frames (BA: 1 KB) and an 8 KB/255-frame buffer (BA: 2 KB), and additionally supports Modbus RTU master/slave. Choose HF for higher traffic and protocol requirements.
Q5: Does the module need an external power supply? What about the front connector?
A: No. It is powered directly from the S7-1500 backplane bus with only approx. 0.6 W power loss. The 15-pin Sub-D socket is built in, so no 40-pin front connector is required.