6ES7214-1AF40-0XB0

The 6ES7214-1AF40-0XB0 is the CPU 1214FC fail-safe compact CPU of the Siemens SIMATIC S7-1200F series, running standard user programs and safety programs in a single controller. It provides 14 × 24V DC digital inputs, 10 × 24V DC transistor outputs, and 2 × 0–10V analog inputs on board, with 200 KB of work memory and safety functions up to SIL 3 (IEC 61508) and PL e (ISO 13849-1). It suits machine builders and retrofit projects that need emergency stop, safety door, or two-hand control functions on a single machine or small line.
 
  • 6ES7214-1AF40-0XB0

  • Siemens

Availability:
Quantity:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
kakao sharing button
snapchat sharing button
telegram sharing button
sharethis sharing button

The CPU 1214FC merges safety control and standard control into one device. The standard program uses the full S7-1200 instruction set, while the safety program runs in a separate F-runtime group called by the F organization block (default 100 ms cyclic interrupt, priority 9) without interfering with standard logic. Safety code can only be written in F-LAD/F-FBD using TÜV-certified safety blocks; compilation generates a safety signature (CRC) that changes with any modification and requires a fresh download. On the safety side, PROFIsafe links the CPU to SM 1226 fail-safe modules and distributed F-devices, transporting process data, status bytes, and checksums securely. The CPU integrates one PROFINET interface (RJ45, 100 Mbit/s, PROFINET IO controller/device, PROFIsafe, OPC UA server, web server) and retains high-speed counting, pulse outputs, PID, and positioning axes for routine motion and control tasks beyond safety functions.

● Standard and safety in one CPU: parallel execution of standard and safety programs, eliminating separate safety relays

● SIL 3 / PL e safety rating: compliant with IEC 61508 (SIL 3) and ISO 13849-1 (PL e)

● Native PROFIsafe: safe communication with SM 1226 F-DI/F-DQ modules and distributed F-devices

● 200 KB work memory: shared by standard and safety programs; 4 MB load memory plus memory card option

● Full technology functions: 6 high-speed counters (up to 100 kHz), 4 × 100 kHz pulse outputs, 8 positioning axes, PID

● Communication and diagnostics: PROFINET, OPC UA server, MODBUS, web server, 2 configurable traces

Item

Specification

Order No. / Model

6ES7214-1AF40-0XB0 / CPU 1214FC DC/DC/DC (S7-1200F)

Firmware / Engineering

V4.7 / STEP 7 (TIA Portal) V20 or higher; STEP 7 Safety license required for safety programs

Safety Rating

Up to SIL 3 (IEC 61508) and PL e (ISO 13849-1) in safety mode; PROFIsafe supported

Onboard Digital Inputs

14 × 24V DC, sink/source capable; 6 usable for high-speed counting

Input Levels / Delay

"1": 15V DC at 2.5 mA; "0": 5V DC at 1 mA; delay 0.1 µs to 20 ms, parameterizable

Onboard Digital Outputs

10 × 24V DC transistor (sourcing), 4 of them 100 kHz pulse train outputs

Output Capacity / Delay

0.5 A per point (resistive), 5 W lamp load; max. 1 µs / 5 µs switching delay

Onboard Analog Inputs

2 × 0–10V, 10 bit including sign, input resistance ≥100 kΩ, 625 µs conversion per channel

Counting / Pulse

6 counters up to 100 kHz (3 × 100 kHz + 3 × 30 kHz single-phase); 4 PTO outputs up to 100 kHz

Memory

Work memory 200 KB; load memory 4 MB (extendable via SIMATIC memory card); retentive 14 KB

Instruction Times

Bit 0.08 µs; word 1.7 µs; floating point 2.3 µs

Expansion

1 signal board (SB) + 8 signal modules (SM, incl. SM 1226 F-modules) + 3 communication modules (CM)

Interfaces

1 × PROFINET (RJ45, 100 Mbit/s, isolated); IO controller for up to 16 devices; OPC UA server (Basic license), MODBUS, web server

Supply / Current

24V DC (20.4 to 28.8V, reverse-polarity protected); 500 mA CPU only, 1500 mA max. with all expansion

Power Loss

Typ. 12 W

Clock Backup

Hardware real-time clock, maintenance-free backup approx. 480 h (typ.), ≤60 s/month at 25°C

Dimensions / Weight

110 × 100 × 75 mm / approx. 415 g; IP20

Ambient Temperature

0 to 55°C (horizontal) / 0 to 45°C (vertical); storage -40 to 70°C

Approvals

CE, UL, cULus, FM, RCM, KC, marine; TÜV type examination for functional safety

5. Frequently Asked Questions (FAQ)

Q1: How does the 1214FC differ from a standard 1214C? Can it be swapped in directly? The 1214FC is the fail-safe CPU (order no. 1AF40) and can execute safety programs at up to SIL 3 / PL e in addition to standard control; a standard 1214C (e.g. 1AG40) has no F-runtime group and cannot perform safety functions. Mounting and wiring are essentially identical, but the project must be re-configured and recompiled for an F-CPU — downloading a standard project to an FC is rejected by the safety signature check.

Q2: Can onboard I/O alone handle safety functions? What else is needed? The onboard 14 DI / 10 DQ can be used as F-I/O in the safety program (the usable channel count depends on firmware and configuration). For more safety points or higher drive capability, add SM 1226 fail-safe modules (e.g. F-DI 16×24V DC, F-DQ 4×24V DC/2A). A STEP 7 Safety license (Basic or Advanced) is also required, along with safety-compliant wiring, validation, and acceptance documentation.

Q3: Are the safety and standard programs separated? Do they interfere? They run in parallel in the same CPU but are isolated: the safety program lives in a separate F-runtime group invoked by the F organization block (default 100 ms cyclic interrupt) and may only use F-LAD/F-FBD with certified safety blocks, while the standard program uses the full instruction set. Every change to the safety program alters the safety signature and triggers a STOP→RUN sequence, so plan modifications during scheduled downtime.

Q4: Will this model remain available long term? Siemens lists the product with a phase-out effective 1 November 2026 (successor: S7-1200 G2 series). Spare-part and maintenance purchases remain possible, but new projects should evaluate the corresponding G2 fail-safe CPU to avoid future lead-time constraints.

Previous: 
Next: 

PRODUCTS

PRODUCTS

QUICK LINKS

CONTACT

+86-176-2073-4453
No. 858 Dujuan Road, Wangyue Subdistrict, Hunan Xiangjiang New Area,China
© 2026 Hunan Dream Road Electrical Technology Co., Ltd. All Rights Reserved. 
Privacy Policy            Sitemap