6ES7368-3BC51-0AA0
Siemens
| Availability: | |
|---|---|
| Quantity: | |
In a multi-tier S7-300 configuration, the central rack (CR) carries the CPU and IM 360, while expansion racks (ER) carry IM 361 plus the associated signal modules. The dedicated connection cable establishes the bus link between them, so the CPU accesses modules in the expansion rack just like local I/O. The cable is 2.5 m long with shielded bus connectors at both ends that plug into the dedicated ports of the IM 360 and IM 361 — no extra wiring or configuration is needed — and keyed housings prevent reversed insertion. An S7-300 system supports up to three expansion racks connected in a cascade, and each expansion rack requires its own power supply module. As an original accessory, the cable is matched to the IM 360/IM 361 pair, and the length is selected according to the actual cabinet spacing.
● Original matching accessory: designed together with the IM 360 / IM 361 interface modules, plug-and-play
● 2.5 m standard length: suits tiered racks and short-to-medium cabinet spans
● Shielded bus construction: noise-resistant design for stable expansion-rack communication
● No configuration required: no parameter settings; the CPU recognizes the expansion rack once plugged in
● Keyed connectors: positioning at both ends prevents reversed insertion and interface damage
● Multi-tier expansion: with IM 360/361, supports up to three expansion racks
Item | Specification |
Order No. / Model | 6ES7368-3BC51-0AA0 |
Product Name | SIMATIC S7-300 connecting cable 2.5 m (IM 360/361) |
Product Type | PLC accessory (inter-rack bus connection cable) |
Cable Length | 2.5 m |
Applicable Interface Modules | IM 360 (central rack side) / IM 361 (expansion rack side) |
Connection | Between central and expansion racks, or cascaded between expansion racks |
System Expansion | Up to 3 expansion racks; each rack needs its own power supply module |
Compatible System | SIMATIC S7-300 (including related ET 200M configurations) |
Connector Type | Dedicated bus connectors, keyed at both ends |
Configuration | No separate configuration; recognized with the rack hardware configuration |
Installation | Routed between racks or along cabinet cable ducts |
Packaging Unit | 1 cable per unit |
Q1: Is this a module or an accessory? It is an accessory. The cable contains no electronics; it only carries the bus connection between IM 360 and IM 361 and must be used with those interface modules. On its own it cannot extend a rack.
Q2: What if 2.5 m is not long enough? The S7-300 range includes original connection cables in other lengths, selectable to match the actual rack spacing. Extending or splicing the cable yourself is not recommended, as it can degrade bus signal quality and communication stability.
Q3: Does an expansion rack need a separate power supply? Yes. Every expansion rack requires its own power supply module. The connection cable carries only backplane bus communication, not the expansion rack's operating power.
Q4: How many racks can one CPU support? An S7-300 system supports up to three expansion racks, cascaded with IM 360/IM 361. The CPU backplane current budget and rack count limits must also be verified.