When a CompactLogix system requires more I/O modules than one bank can hold, or when separate power supplies are needed for different I/O groups, the 1769-CRL1 routes the bus from the right end of one bank to the left end of the adjacent bank, creating a "physically separate, electrically unified" expansion. Its compact 0.3 m length suits banks mounted side by side in space-constrained panels, eliminating the cable clutter and noise pickup associated with coiled long cables. A system supports up to two expansion cables and three I/O banks, each powered by its own 1769 power supply. Dedicated bus connectors allow plug-and-play installation, and termination caps are included.
● Compact 0.3 m length: ideal for adjacent banks, maximizing panel routing space
● Right-to-left direction: connects the right end of one bank to the left end of the next, matching 1769 backplane polarity
● Three-bank architecture: up to two expansion cables per system, forming three independently powered I/O banks
● Reliable signal integrity: shielded construction suppresses EMI for stable cross-bank communication
● Flexible zoned power: independent power supplies per bank simplify load distribution and maintenance
● Tool-free installation: dedicated bus connectors plug straight in, termination caps included
Item | Specification |
Catalog Number | 1769-CRL1 |
Product Type | Compact I/O bus expansion cable (right-to-left) |
Cable Length | 0.3 m (305 mm / 1 ft) |
Expansion Direction | Right-to-Left |
Connector Type | 1769 Compact I/O dedicated bus connector |
System Banks | Up to 3 banks (max. 2 expansion cables) |
Power Supply | Each bank powered by its own 1769 power supply |
Operating Temperature | 0~60°C (32~140°F) |
Storage Temperature | -40~85°C (-40~185°F) |
Relative Humidity | 5%~95%, non-condensing |
Compatibility | 1769 Compact I/O modules and CompactLogix controllers (incl. DriveLogix 5730) |
Included Accessories | Termination caps |
Certifications | UKCA, RINA, ABS and other marine/regional certifications |
Q1: How do I choose between the 1769-CRL1 and the 1769-CRL3? Both expand right-to-left; only the length differs. The CRL1 is 0.3 m for adjacent banks, while the CRL3 is 1 m for layouts with greater bank spacing.
Q2: What is the difference between the 1769-CRL1 and the 1769-CLL3? The CRL1 is a right-to-left expansion cable; the CLL3 is a left-to-left cable. Choose according to the actual mounting orientation.
Q3: How many expansion cables can one system use? A maximum of two, forming up to three I/O banks. Beyond that, use another approach such as distributed I/O.
Q4: Does each bank need its own power supply after expansion? Yes. The cable carries backplane communication only; each bank requires its own 1769 power supply for its local modules.