6ES7215-1AG40-0XB0
Siemens
| Availability: | |
|---|---|
| Quantity: | |
The CPU 1215C is the wider sibling of the 1212C, packing a fuller I/O set and dual Ethernet into a 130 mm-wide body: bit instruction execution is 0.08 µs. Six inputs can serve as high-speed counter inputs with a total of 6 HSCs (single-phase up to 100 kHz) for incremental encoders, and 4 of the 10 outputs can be configured as PTO/PWM (up to 100 kHz) to drive stepper or servo drives directly with pulse/direction signals. Two onboard analog inputs (0-10V) and two analog outputs (0-20mA) handle simple control loops without extra modules. The two PROFINET ports (RJ45, 10/100 Mb/s) contain an integrated switch for engineering, HMI, CPU interconnection, and PROFINET IO control, giving flexible wiring. For additional I/O, the CPU accepts one signal board, up to eight signal modules, and three communication modules, reaching 284 local digital I/O points and 69 analog channels. Program and data memory is 200 KB with an integrated 4 MB load memory expandable via a SIMATIC memory card; the real-time clock is maintained by a maintenance-free supercapacitor for about 20 days — no battery needed.
● Integrated 14DI / 10DO / 2AI / 2AO: full digital and analog I/O onboard, no expansion for control loops
● Dual PROFINET ports: integrated switch supports line topology or branching, saving an external switch
● High-speed counting and pulses: 6 HSCs (up to 100 kHz); 4 PTO/PWM channels driving steppers/servos directly
● Large memory: 200 KB program/data, 4 MB load memory expandable via SIMATIC memory card
● Strong scalability: 1 signal board + up to 8 signal modules + 3 communication modules; 284 local I/O points
● Maintenance-free: supercapacitor clock backup of about 20 days, no battery; reverse-polarity protected supply
Item | Specification |
Order No. / Model | 6ES7215-1AG40-0XB0 / CPU 1215C, DC/DC/DC |
Onboard I/O | 14 DI 24V DC (6 usable as HSC/technological inputs); 10 DO 24V DC sourcing transistor, 0.5 A per point; 2 AI 0-10V DC; 2 AO 0-20mA DC |
Work Memory | 200 KB (program/data, current firmware) |
Load Memory | 4 MB integrated, expandable via SIMATIC memory card |
Retentive Memory | 14 KB (from firmware V4.5), maintenance-free, no battery |
Execution Speed | Bit 0.08 µs; word 1.7 µs; floating point 2.3 µs |
High-Speed Counters | 6 HSCs; single-phase 3×100 kHz + 3×30 kHz, A/B phase 3×80 kHz |
High-Speed Pulse Outputs | 4 PTO/PWM channels (max. 100 kHz) |
Communication | 2 × PROFINET (RJ45, 10/100 Mb/s, integrated switch); HMI, S7 communication, PROFINET IO |
Expansion | Max. 1 signal board (SB), 8 signal modules (SM), 3 communication modules (CM) |
Local I/O Capacity | Up to 284 local digital I/O points; 69 local analog channels |
Supply / Current | 24V DC (20.4 to 28.8V), reverse-polarity protected; rated 500 mA (CPU only), max. 1,500 mA with all expansion; inrush 12 A |
Power Loss | Typ. 12 W |
Backplane / Sensor Supply | 5V DC backplane max. 1,600 mA (for SM/CM); onboard 24V DC sensor supply 400 mA |
Real-Time Clock | Power-fail backup typ. 20 days (supercapacitor, min. 12 days at 40°C); accuracy ±60 s/month |
Dimensions / Weight | 130 × 100 × 75 mm / approx. 0.4 kg |
Protection / Operating Temperature | IP20; -20 to 60°C (horizontal mounting), derate for vertical mounting per system manual |
Engineering Software | STEP 7 (TIA Portal) V20 or later (current firmware V4.7) |
Certifications | CE, cULus, FM, RCM, etc. (see official certificates) |
Q1: What is the difference between AG40, BG40, and CG40? All three are CPU 1215C; they differ in power supply and output type. AG40 is DC/DC/DC (24V DC supply, transistor outputs of 0.5 A per point, supports high-speed pulse outputs). BG40 is AC/DC/RLY (85-264V AC supply, relay outputs of 2 A per point, no high-speed pulses). CG40 is DC/DC/RLY (24V DC supply, relay outputs). For stepper/servo control or high-frequency switching, the transistor version (AG40) is required.
Q2: What are the two PROFINET ports for? Are they two separate subnets? The two RJ45 ports contain an integrated switch and share one IP address, so devices can be wired in a line topology or across two branches without an external switch. In practice, one port often connects to supervisory systems (SCADA/HMI) while the other serves field IO or the next CPU, keeping the cabling tidy. Two independent IP subnets require a communication module (CM).
Q3: What signals can the onboard 2 AI and 2 AO accept? The two analog inputs accept 0-10V voltage signals (potentiometers, transmitters, etc.), and the two analog outputs are 0-20mA current type suitable for drives, control valves, and panel meters — note there is no voltage-output variant, and 4-20 mA devices require conversion in the program. For more channels or RTD/thermocouple measurement, add SM 1231 modules or an analog signal board.
Q4: Is this model still purchasable, or discontinued? The Siemens Industry Mall marks this product as phased out from 1 November 2026; the classic S7-1200 is gradually being replaced by the S7-1200 G2 series. Spare parts for existing installations remain procurable, but for new projects we recommend also evaluating the corresponding S7-1200 G2 model to avoid future lead-time constraints.