6ES7278-4BD32-0XB0
Siemens
| Availability: | |
|---|---|
| Quantity: | |
The SM 1278 gives the S7-1200 IO-Link communication capability. Each port connects one IO-Link slave through a standard M12 connector, and a single 3-wire cable carries both power and bidirectional data, so process values can be read while device parameters and diagnostics are read or written. The module supports COM1 (4.8 kBd), COM2 (38.4 kBd), and COM3 (230.4 kBd) and adapts automatically to the rate supported by the connected device — no manual setting required. Parameters are stored in the master according to V1.1, providing central data storage so a replacement device is automatically re-parameterized, eliminating on-site recommissioning. Diagnostics are parameterizable per port for fast identification of wire break, short circuit, or missing device. Configuration requires STEP 7 (TIA Portal) V13 or later, and IO-Link parameterization additionally requires S7-PCT V3.2 or later. The module is powered by an external 24V DC supply and draws no current from the CPU backplane.
● Four IO-Link master ports: compliant with IO-Link V1.1, one 3-wire device per port
● Automatic rate adaptation: COM1 / COM2 / COM3 matched to the connected device
● Central data storage: parameters held in the master and pushed to replacement devices, minimizing downtime
● Port-level diagnostics: individually parameterizable per port for fast fault location
● External 24V supply: no backplane current draw, simplifying multi-module expansion
● Firmware update capable: module firmware can be upgraded in software to extend service life
Item | Specification |
Order No. / Model | 6ES7278-4BD32-0XB0 / SM 1278 4×IO-Link Master |
Product Type | S7-1200 signal module (IO-Link master) |
Ports | 4 IO-Link ports, M12 A-coded, 3-wire connection |
IO-Link Specification | V1.1 |
Transmission Rate | COM1 4.8 kBd / COM2 38.4 kBd / COM3 230.4 kBd, automatic adaptation |
Process Data | Up to 32 bytes input / 32 bytes output per port |
Parameter Storage | Central data storage per V1.1 (device parameters held in the master) |
Diagnostics | Port-by-port parameterizable diagnostics; channel status LEDs plus DIAG LED |
Power Supply | External 24V DC (19.2 to 28.8V); 0 mA from the backplane bus |
Current Consumption | Typ. 65 mA (external 24V DC) |
Module Count | Up to 8 SM 1278 modules depending on the CPU model |
Degree of Protection | IP20 (for cabinet installation) |
Operating Temperature | Horizontal rail mounting (vertical): 0 to 55°C; vertical rail mounting (horizontal): 0 to 45°C |
Relative Humidity | Max. 95% at 25°C, no condensation |
Dimensions (W×H×D) | 45 × 100 × 75 mm |
Engineering Software | STEP 7 (TIA Portal) V13 or later; S7-PCT V3.2 or later for IO-Link configuration |
Mounting | Right-side expansion bus of the S7-1200 CPU, DIN rail |
Q1: How does IO-Link wiring differ from standard DI/DO? Standard DI/DO carries only on/off states. IO-Link uses one 3-wire cable for both power and bidirectional communication, so besides process values it reads and writes device parameters, identifies the device type, and retrieves diagnostics — and restores parameters automatically after replacement.
Q2: Does the module need an external power supply? Yes. It is powered by an external 24V DC supply (19.2 to 28.8V) drawing typically 65 mA, with 0 mA from the backplane. Connect both L+ and M, otherwise the ports provide no output.
Q3: How many SM 1278 modules per CPU, and how many devices per module? Each SM 1278 supports four IO-Link devices. The number of modules depends on the CPU model, with up to 8 modules supported; verify against the CPU's expansion capability.
Q4: Can it be used with older CPUs lacking onboard IO-Link, and what cable is required? Yes, provided the CPU supports this signal module. Use standard M12 shielded IO-Link cable, no longer than 20 m, to ensure communication quality.