6ES7223-3BD30-0XB0
Siemens
| Availability: | |
|---|---|
| Quantity: | |
The SB 1223 (200 kHz version) is built for speed. Its 2 inputs can be used directly as high-speed counter (HSC) clock inputs — up to 200 kHz single-phase or 160 kHz quadrature — while the 2 solid-state MOSFET outputs (sink or source wiring) support pulse train output (PTO) from 2 Hz up to 200 kHz with a switching delay of only about 1.5 µs, driving the pulse command inputs of stepper or servo drives directly. Input filter times are parameterizable from 0.2 to 12.8 ms in groups, balancing responsiveness and noise immunity. The board is plugged into the CPU's front-panel socket, completing electrical and mechanical connection in one step; removable terminals allow replacement without unwiring point by point. Field-to-logic isolation is 500V AC for 1 minute, and TIA Portal recognizes the board automatically upon insertion.
● 200 kHz high-speed channels: HSC clock inputs 200 kHz single-phase / 160 kHz quadrature; PTO output up to 200 kHz
● Ultra-fast switching: solid-state MOSFET outputs, ~1.5 µs switching delay, no contact wear
● Zero-slot expansion: plugs into the CPU front-panel socket — no expansion slot, no mounting-size change
● Sink/source universal outputs: MOSFET outputs accept either wiring style for flexible hookup
● Configurable input filters: 0.2 to 12.8 ms, parameterizable in groups
● Tool-free replacement: removable terminals plus status LEDs for quick maintenance
Item | Specification |
Order No. / Model | 6ES7223-3BD30-0XB0 / SB 1223, DI 2×24V DC, DQ 2×24V DC, 200 kHz |
Product Type | S7-1200 digital I/O signal board (SB), plugged onto the CPU front panel |
Digital Inputs | 2 points, 24V DC source type ("1": below L+ −10V at ≥2.9 mA; "0": above L+ −5V at ≤1.4 mA) |
Input Voltage | Rated 24V DC (continuous 28.8V); surge 35V DC for 0.5 s |
HSC Clock Inputs | Single-phase max. 200 kHz; quadrature max. 160 kHz |
Input Filter | 0.2 / 0.4 / 0.8 / 1.6 / 3.2 / 6.4 / 12.8 ms, selectable in groups |
Digital Outputs | 2 points, solid-state MOSFET, sink or source wiring, 24V DC (20.4 to 28.8V) |
Output Capacity | Max. 0.1 A per point (surge 0.11 A); 0.2 A per common; no built-in overload protection |
Output Signal / Delay | "1" min. L+ −1.5V; "0" max. 1.0V; switching delay approx. 1.5 µs (rise/fall) |
PTO Pulse Output | Max. 200 kHz, min. 2 Hz; on RUN→STOP keep last value or substitute (default 0) |
Cable Length | Inputs/outputs: max. 50 m shielded twisted pair |
Isolation | 500V AC for 1 minute between field side and logic side; 1 isolation group |
Backplane / 24V Current | Backplane 5V DC typ. 35 mA; 24V DC 7 mA per input + 30 mA shared |
Power Loss | Typ. 1.0 W |
Dimensions / Weight | 38 × 62 × 21 mm / approx. 35 g |
Configuration | STEP 7 (TIA Portal); recognized automatically on insertion; no jumpers or address setting |
Q1: What is the difference between an SB signal board and an SM signal module? How many boards fit on one CPU? SM modules plug into the CPU's right-side expansion bus and occupy module slots; SB signal boards plug into the dedicated socket on the CPU front panel, occupying no slots and leaving the CPU's mounting dimensions unchanged — ideal for very compact machines. Classic S7-1200 CPUs typically support up to 1 signal board each (check the technical specifications of the selected CPU). For more I/O points, choose SM modules instead.
Q2: Why is 200 kHz emphasized? Which applications need it? This is the high-speed version of the S7-1200 signal boards: the 2 inputs work as HSC clock inputs (200 kHz single-phase, 160 kHz quadrature) and the 2 outputs deliver PTO up to 200 kHz. Typical uses are sending pulse/direction commands to stepper or servo drives and reading incremental encoders for speed or position. For ordinary digital acquisition and solenoid control, the standard SB 1223 (6ES7223-0BD30) is sufficient and more economical.
Q3: How are the inputs wired — NPN or PNP sensors? The inputs are of the source type, referenced to L+: a "1" signal is below L+ −10V (≥2.9 mA) and a "0" is above L+ −5V. This suits NPN (sinking) open-collector sensors and high-speed pulse sources. When using PNP sensors, check level compatibility and add a converter stage if necessary. Use shielded twisted-pair cable up to 50 m.
Q4: The outputs are rated only 0.1 A — what can they drive? The 0.1 A rating defines a "signal-level" output: pulse and direction command inputs of stepper/servo drives, small electronic loads, and indicator circuits. It cannot directly drive solenoid valves or contactor coils — use an SM 1223 transistor or relay module for such loads. As the outputs have no built-in overload protection, provide external fusing; the total current per common is limited to 0.2 A, so the two outputs must not be simultaneously overloaded.