8BVI0055HWS0.000-1
Siemens
| Availability: | |
|---|---|
| Quantity: | |
The module operates over a wide DC bus range (260 to 800 VDC continuous) with selectable switching frequencies of 5 / 10 / 20 kHz, balancing low-speed smoothness against dynamic response. It integrates a motor holding brake control output (24 VDC / 1.1 A, no external relay required), 2 enable inputs and 2 high-precision trigger inputs (digitally filtered, only ±0.5 µs jitter), a temperature sensor input and 2 × 24 VDC auxiliary outputs, plus 2 plug-in module slots for flexible expansion with EnDat, SinCos, HIPERFACE and other encoder interfaces. At only 53 mm wide (1 module slot), it installs side by side with ACOPOSmulti power supply modules in the cabinet, supports dynamic node allocation (DNA), and holds CE, UKCA, UL/cULus and KC certifications for compliant deployment worldwide.
High-Precision Single-Axis Drive7.6 A continuous (18.9 A peak), 5.5 kW continuous power, max. output frequency 598 Hz
Selectable Switching Frequency5 / 10 / 20 kHz — trade off low-speed smoothness against quiet operation
Integrated Holding Brake Control24 VDC / 1.1 A brake output drives the motor brake directly, no external relay
2 Plug-in Module SlotsExpandable with EnDat 2.2, SinCos, HIPERFACE, incremental and other encoder interfaces
High-Precision Trigger Inputs2 trigger inputs with digital filtering, only ±0.5 µs jitter for precise synchronization
Global CertificationsCE / UKCA / UL cULus E225616 / KC, functional safety supported
Model | 8BVI0055HWS0.000-1 (ACOPOSmulti inverter module, single-axis, 7.6 A, HV, wall mounting) |
|---|---|
DC bus voltage | Nominal 750 VDC; continuous operation 260 ~ 800 VDC; DC bus capacitance 165 µF |
Output power | Continuous 5.5 kW; continuous power consumption (bus side) 5.6 kW |
Output current | Continuous 7.6 A (RMS); peak 18.9 A (RMS) |
Switching frequency | Nominal 5 kHz (selectable 5 / 10 / 20 kHz); max. output frequency 598 Hz |
Motor cable length | Max. 25 m at 5 / 10 kHz; max. 10 m at 20 kHz |
Motor connection | 1 connection (U, V, W, PE) with shield connection |
Holding brake output | 1 output, 24 VDC, 1.1 A continuous, max. switch-off energy 1.5 Ws, max. switching frequency 0.5 Hz |
Enable / trigger inputs | 2 each, 24 VDC (max. 30 VDC); trigger inputs digitally filtered, jitter ±0.5 µs |
Auxiliary outputs | 2 × 24 VDC ±6% (250 mA slow-blow electronic fuse, automatic reset) |
Temperature sensor input | 1 input (resistance range 500 Ω ~ 5 kΩ) |
Plug-in module slots | 2 (encoder interfaces and other ACOPOSmulti plug-in modules) |
Power supply | 25 VDC ±1.6% (backplane supply), max. consumption 12 W + slot and 24 V output consumption |
Standby losses | 7.5 W |
Mounting / cooling | Wall mounting, natural convection cooling; vertically hanging or horizontal, face up |
Dimensions / weight | 53 mm (W) × 317 mm (H) × 263 mm (D), 1 module slot; approx. 2.7 kg |
Protection | IP20 (EN 60529), overvoltage category III, pollution degree 2 |
Ambient conditions | Operation 5 ~ 40 °C (max. 55 °C); storage -25 ~ 55 °C; transport -25 ~ 70 °C; humidity 5 ~ 85% RH |
Altitude | Nominal 0 ~ 500 m (up to 4000 m with derating) |
Certifications | CE, UKCA, UL cULus E225616, KC, functional safety supported |
Q1: What role does the 8BVI0055HWS0.000-1 play in the system?
It is the single-axis inverter module of the ACOPOSmulti drive system. Drawing from the central DC bus (750 VDC), it drives one servo motor via vector control, delivering high-precision position, velocity and torque control — the actuating core of the motion control system.
Q2: What motor power can it drive?
It delivers 5.5 kW continuous power at 7.6 A continuous current, with a short-term peak current of 18.9 A and a maximum output frequency of 598 Hz, covering most low- to mid-power synchronous and asynchronous servo motors. Please confirm the motor's rated current and overload requirements during selection.
Q3: How should the switching frequency be selected?
Three settings are available: 5 / 10 / 20 kHz. Use 5 kHz for lowest losses in standard applications; 10 kHz balances dynamics and losses; 20 kHz offers the quietest, smoothest operation, but the allowable motor cable length drops to 10 m and derating applies.
Q4: Can it control the motor holding brake directly?
Yes. The module integrates one holding brake control output (24 VDC, 1.1 A continuous, max. switch-off energy 1.5 Ws) with overload, short-circuit, open-circuit and undervoltage protection. The motor brake can be driven directly without an external relay, simplifying cabinet wiring.
Q5: Which encoder interfaces are supported?
The module offers 2 plug-in module slots accepting EnDat 2.1/2.2, SinCos, HIPERFACE, SSI, incremental (5 V/24 V) and Resolver encoder interface modules, compatible with the feedback systems of major motor brands. Encoder emulation outputs (RS422) and analog/digital I/O expansions are also available as plug-in options.
Q6: How is the module mounted, and how much cabinet space does it use?
It is wall-mounted with natural convection cooling (fan-free and maintenance-free), and supports vertically hanging or horizontal, face-up orientation. At only 53 mm wide (1 module slot), 317 mm high and 263 mm deep, and weighing approx. 2.7 kg, it installs side by side with ACOPOSmulti power supply and auxiliary modules on the same backplane.
Q7: What protective features does the module include?
It provides overvoltage, undervoltage, overcurrent, overtemperature and short-circuit protection. Motor temperature can be monitored via the temperature sensor input (500 Ω ~ 5 kΩ, e.g., KTY84/PT1000); the holding brake output and 24 VDC auxiliary outputs each have independent protection for safe drive and motor operation.
Q8: Which certifications does the module have?
It is CE and UKCA certified, complies with UL cULus E225616 for power conversion equipment, holds KC certification and supports functional safety, meeting market access requirements in Europe, North America and Korea.