8B0C0320HW00.002-1
Siemens
| Availability: | |
|---|---|
| Quantity: | |
The module operates over a wide DC bus range (260 to 800 VDC continuous) and delivers full output power from 315 VDC bus voltage upward. The 24 VDC outputs feature comprehensive protection against no-load, overload, short-circuit, feedback voltage and overtemperature conditions. Output 1 is protected by a 32 A electronic slow-blow fuse with automatic reset, and output 2 by a 5 A electronic fuse — faults recover automatically without fuse replacement. The module also includes an internal system power supply (25 VDC ±1.6%) and a remotely controllable enable input (24 VDC signal). At only 53 mm wide (1 module slot), it installs side by side with ACOPOSmulti power supply and inverter modules in the cabinet. CE, UKCA, UL/cULus and KC certifications ensure compliant deployment in industrial environments worldwide.
DC Bus PoweredWide 260 ~ 800 VDC operating range; full output power from 315 VDC bus voltage
Dual 24 VDC Outputs1×32 A + 1×5 A, 800 W continuous power, 42 A peak current (<4 s)
Comprehensive ProtectionNo-load / overload / short-circuit / feedback / overtemperature protection; SELV / PELV isolated output
Electronic Fuses with Auto Reset32 A / 5 A slow-blow electronic protection recovers automatically after a fault — maintenance-free
Compact, Space-SavingOnly 53 mm wide (1 module slot), installs alongside other ACOPOSmulti modules
Global CertificationsCE / UKCA / UL cULus E225616 / KC
Model | 8B0C0320HW00.002-1 (ACOPOSmulti auxiliary supply module, 32 A, HV, wall mounting, 24 VDC out 1×32 A + 1×5 A) |
|---|---|
DC bus input | Nominal 750 VDC; continuous operation 260 ~ 800 VDC; full continuous power ≥315 VDC |
Continuous power consumption | Max. 880 W (DC bus capacitance 220 nF) |
24 VDC output | 24 VDC ±6%; continuous current 32 A DC; continuous power 800 W; peak current (<4 s) 42 A |
Outputs / fusing | Out 1: 32 A (slow-blow electronic fuse, automatic reset); Out 2: 5 A (slow-blow electronic fuse, automatic reset) |
Output performance | Startup delay max. 1 s; startup time approx. 5 ~ 20 ms; residual ripple typ. 50 mVSS |
Protective measures | No-load proof, overload-proof, short-circuit proof, feedback protection (max. 26 / 35 VDC when switched off), overtemperature protection |
Isolation | Output/input isolation meets SELV / PELV requirements; dielectric strength to ground ±50 VDC |
Internal system power supply | 25 VDC ±1.6% (ACOPOSmulti backplane supply) |
Output enable control input | 24 VDC (max. 30 VDC); ON threshold <5 V / OFF threshold >15 V |
Mounting / orientation | Wall mounting; vertically hanging or horizontal, face up |
Dimensions / weight | 53 mm (W) × 317 mm (H) × 263 mm (D), 1 module slot; approx. 3.2 kg |
Protection | IP20 (EN 60529), overvoltage category III, pollution degree 2 |
Ambient temperature | Operation 5 ~ 40 °C (max. 55 °C, no derating above 40 °C); storage -25 ~ 55 °C; transport -25 ~ 70 °C |
Humidity / altitude | Operation 5 ~ 85% RH; nominal altitude 0 ~ 500 m (up to 4000 m with derating of 80 W per 1000 m above 500 m) |
Certifications | CE, UKCA, UL cULus E225616 (power conversion equipment), KC |
Mandatory accessories | Terminal block set 8BZ0C032000.002-1A |
Q1: What is the difference between an auxiliary supply module and an ACOPOSmulti power supply module?
The power supply module (e.g., 8BVP series) rectifies three-phase mains into the 750 VDC DC bus that powers the servo inverter modules. The auxiliary supply module (this 8B0C series) draws from that DC bus and converts it into an isolated 24 VDC control supply for external 24 V devices such as controllers, I/O and encoders. Used together, they form the complete power architecture of the drive system.
Q2: What is the output capability of the module?
It provides two 24 VDC outputs: Output 1 delivers 32 A continuous (with a 32 A electronic slow-blow fuse) and Output 2 delivers 5 A continuous (5 A electronic fuse), for a total continuous power of 800 W. Short-term peak current reaches 42 A for up to 4 seconds. Full power is available at DC bus voltages of 315 VDC and above.
Q3: What protective measures do the outputs include?
The outputs are no-load proof, overload-proof and short-circuit proof, include feedback voltage protection (withstanding up to 26 / 35 VDC when switched off) and overtemperature protection. Both outputs use electronic fuses with automatic reset — after a fault clears, power is restored automatically without fuse replacement, minimizing downtime.
Q4: What are typical applications for this module?
It is designed to supply external 24 V devices in automation equipment, such as B&R controllers and I/O modules, encoder buffering battery sets, fans, sensors and relays — keeping the control loop reliably powered while the main supply is starting up or in standby.
Q5: How is the module mounted, and how much cabinet space does it use?
It is wall-mounted and supports vertically hanging or horizontal, face-up orientation. At only 53 mm wide (1 module slot), 317 mm high and 263 mm deep, and weighing approx. 3.2 kg, it installs side by side with ACOPOSmulti power supply and inverter modules on the same backplane, saving cabinet space.
Q6: Is the output voltage stable, and can it be switched remotely?
Output is 24 VDC ±6% with a typical residual ripple of only 50 mVSS and a startup time of approx. 5~20 ms. The module provides an output enable control input (24 VDC signal, ON threshold <5 V, OFF threshold >15 V) that lets the controller switch 24 VDC Output 1 remotely (ON delay max. 25 ms, OFF delay max. 0.25 ms).
Q7: Which accessories are required for installation?
The mandatory terminal block set is 8BZ0C032000.002-1A (including 8TB3104.201M-11, 8TB2104.2010-00 and 8TB2106.2010-00 screw-clamp terminals). Output 1 terminals accept flexible fine-stranded wires from 0.25 to 6 mm²; Output 2 and control input terminals accept 0.25 to 2.5 mm². An optional replacement fan module 8BXF001.0000-00 is also available.
Q8: Which certifications does the module have?
It is CE and UKCA certified, complies with UL cULus E225616 for power conversion equipment, and holds KC certification, meeting market access requirements in Europe, North America and Korea.
Provide your equipment model and application scenario, and our engineers will deliver professional selection and configuration advice.
Contact Us
© 2026 Industrial Automation · Specifications on this page are sourced from the manufacturer's public documentation and are for reference only; the official datasheet takes precedence.