1772989321@qq.com    +86-17620734453
English

Product Detail

Home » Products » 6ES7511-1AK01-0AB0

Product Category

Contact Us

6ES7511-1AK01-0AB0

The 6ES7511-1AK01-0AB0 is the CPU 1511-1 PN, the smallest standard CPU of the SIEMENS SIMATIC S7-1500 family, aimed at small and mid-size automation projects: standalone machines, packaging and printing equipment, material handling, HVAC and water supply, small pump stations and production cells. It offers 150 KB of work memory for program and 1 MB for data with a 60 ns bit operation time, and one PROFINET IO IRT interface with an integrated 2-port switch for line, star or MRP ring topologies, connecting ET 200MP / ET 200SP distributed I/O, drives, servos and HMI panels.

Compared with the previous S7-300 generation, the CPU 1511-1 PN delivers higher processing performance in the same footprint, consistent plain-text diagnostics, no-programming device replacement, and a small display on the front panel (3.45 cm) for checking IP address, diagnostics and operating state on site — considerably shortening commissioning and troubleshooting. Isochronous mode (IRT) and prioritized startup support time-critical motion and high-speed process tasks, while the integrated web server allows diagnostics to be viewed remotely from a browser.

Important to note: S7-1500 CPUs have no integrated load memory — a SIMATIC Memory Card (max. 32 GB) must be inserted before a program can be downloaded or run. Program, firmware, recipes and archives all live on the card, so a CPU swap becomes a simple card transfer, which is a key reason spare-part replacement on S7-1500 is so fast.
  • 6ES7511-1AK01-0AB0

  • Siemens

Availability:
Quantity:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
kakao sharing button
snapchat sharing button
telegram sharing button
sharethis sharing button

Processing performance: 60 ns for bit operations, 72 ns for word operations, 96 ns for fixed-point and 384 ns for floating-point arithmetic. Up to 2000 program blocks (OB/FB/FC/DB) in total, a single DB up to 1 MB, and individual FB/FC/OB up to 150 KB. Bit memory (M) is max. 16 KB and the total retentive data area max. 128 KB; the I/O address area is 32 KB for inputs and 32 KB for outputs, all located in the process image. There are 2048 S7 counters and 2048 S7 timers; the number of IEC counters and timers is limited only by work memory, and retentivity is configurable. A hardware real-time clock runs maintenance-free without a backup battery.

Communication and networking: interface X1 is PROFINET IO IRT with an integrated 2-port switch (2 × RJ45), supporting PROFINET IO controller and device operation, S7 communication, open IE communication, web server, MRP/MRPD media redundancy (as redundancy manager and/or client, up to 50 devices in the ring), PROFIenergy and prioritized startup (up to 32 devices). Up to 128 PROFINET IO devices can be connected (of which max. 64 with IRT, 128 with RT); including AS-i and PROFIBUS networks the system can handle up to 256 distributed I/O devices in total, and the IRT send cycle can start at 250 µs. The central rack accepts up to 32 modules (the CPU plus 31 S7-1500 modules).

Electrical and mechanical: rated supply DC 24 V (permissible 19.2–28.8 V), rated input current 0.7 A, maximum inrush 1.9 A, power-failure buffering 5 ms, typical power loss 5.7 W, and 10 W available to feed the backplane bus. The design is maintenance-free with no backup battery. Dimensions are 35 × 147 × 129 mm, net weight approx. 0.51 kg, degree of protection IP20, ambient temperature 0 to +60 °C for horizontal and 0 to +40 °C for vertical mounting on the S7-1500 rail. Engineering is done with STEP 7 (TIA Portal) V13 SP1 or higher in LAD, FBD, STL, SCL and GRAPH; integrated motion control supports technology objects such as positioning axes, velocity axes and external encoders (up to 8 axes, depending on CPU resources and object type).

150 KB / 1 MB Memory

150 KB program, 1 MB data, up to 2000 blocks — sized for small machines and recipe handling.

60 ns Bit Performance

60 ns bit, 72 ns word, 384 ns floating point for the shortest possible scan cycles.

PROFINET IRT, 2 Ports

Integrated switch for line or MRP ring topologies, isochronous mode, up to 128 IO devices.

Display & Web Server

3.45 cm on-board display for IP and diagnostics; browser-based remote diagnostics.

Maintenance-Free

No backup battery; clock and retentive data secured by supercap and memory card.

Fast Spare Swap

Plain-text diagnostics across TIA Portal, HMI and web; card transfer restores the machine.

Product type

SIMATIC S7-1500 standard CPU 1511-1 PN (with display)

Work memory

150 KB program / 1 MB data

Load memory

SIMATIC Memory Card (plug-in, max. 32 GB) — required; no card, no operation

Execution times

Bit 60 ns; word 72 ns; fixed point 96 ns; floating point 384 ns

Program blocks

Max. 2000 in total; DB up to 1 MB; individual FB/FC/OB up to 150 KB

Bit memory / retentive

M area max. 16 KB; total retentive area max. 128 KB

I/O address area

32 KB inputs / 32 KB outputs (all in the process image)

Counters / timers

2048 S7 counters, 2048 S7 timers; IEC counters/timers limited only by memory

Clock

Hardware real-time clock, maintenance-free, no backup battery

Communication interface

1 × PROFINET IO IRT with integrated 2-port switch (2 × RJ45, X1)

Communication functions

PROFINET IO controller/device, S7 communication, open IE, web server, MRP/MRPD, PROFIenergy, prioritized startup, isochronous mode

Connectable IO devices

Max. 128 (max. 64 with IRT); up to 256 distributed I/O devices including AS-i/PROFIBUS

Central rack

Up to 32 modules (CPU + 31 S7-1500 modules); no integrated I/O on board

Motion control

Integrated technology objects (positioning/velocity axes, external encoder), up to 8 axes, subject to CPU resources

Display

3.45 cm (diagonal) LCD for IP address and diagnostics

Supply

DC 24 V (19.2–28.8 V); rated input current 0.7 A; max. inrush 1.9 A; reverse polarity protection

Power loss / backplane

Typical 5.7 W; 10 W available for the backplane bus

Power-failure buffering

5 ms; maintenance-free design (no battery)

Mounting & environment

S7-1500 rail mounting; IP20; 0 to +60 °C horizontal / 0 to +40 °C vertical

Dimensions / weight

W 35 × H 147 × D 129 mm; net weight approx. 0.51 kg

Engineering software

STEP 7 (TIA Portal) V13 SP1 or higher; LAD, FBD, STL, SCL, GRAPH

Lifecycle

Discontinued 2018-05-07 (PM410); successor 6ES7511-1AK02-0AB0

Q1: What is the difference between 1AK01 and the successor 1AK02?

Both are CPU 1511-1 PN with identical memory ratings (150 KB program / 1 MB data, 60 ns). The 1AK02 is a later hardware revision with firmware, component and stability improvements, and is the official successor. When replacing, check two things: the firmware version must match the TIA Portal version used for the project, and projects created in older versions should be verified in a test environment before going live.

Q2: Can it run without a memory card?

No. S7-1500 CPUs have no integrated load memory; a SIMATIC Memory Card (max. 32 GB) is mandatory for downloading, storing and running the program, and a standard SD card cannot be substituted. For spare-part replacement, simply move the card from the old CPU to the new one — the fastest way to restore a line. Keeping a mirrored spare card per machine is strongly recommended.

Q3: Is 150 KB of program memory enough?

150 KB fits small and mid-size machines: logic control, simple recipes and standard communication. Keep in mind that library, communication and diagnostic blocks consume far more than their visible logic suggests. As a rule, keep program usage below 60–70% at the end of the project; if recipes, axis control or OPC UA communication are expected later, choose the 1513-1 PN (300 KB / 1.5 MB) or the 1511-1AL03 (300 KB / 1.5 MB) instead.

Q4: How many PROFINET devices can it handle, and how should the network be planned?

Up to 128 PROFINET IO devices (max. 64 with IRT), or up to 256 distributed I/O devices in total when AS-i and PROFIBUS are included; an MRP ring supports up to 50 devices, and up to 32 devices may use prioritized startup. Note that the two ports of X1 are a switch inside one interface (one IP address, one subnet) — usable for line or ring topologies, but unlike the 1515-2 PN it does not provide two separate networks. To separate HMI/MES traffic, add a managed switch or a communication module.

Q5: Does it have on-board I/O? How do I add local I/O?

No. The CPU 1511-1 PN is a pure CPU module without integrated digital or analog points (choose the compact CPU 1511C-1PN if integrated I/O is needed). Expand either with S7-1500 signal modules in the central rack (up to 31) or with ET 200MP / ET 200SP distributed I/O stations over PROFINET.

Q6: Which software is required, and which languages are supported?

Only STEP 7 (TIA Portal) V13 SP1 or higher — classic STEP 7 V5.x and S7-200 MicroWIN are not compatible. Supported languages are LAD, FBD, STL, SCL and GRAPH, with configuration, programming, diagnostics and online monitoring all in one platform.

Q7: Can it run safety (F) programs or redundant systems?

No. The CPU 1511-1 PN is a standard CPU and does not support fail-safe (F) programs — safety applications require an F-CPU such as the CPU 1511F-1 PN. It also cannot be used in S7-1500R/H redundant systems; those need the 1513R/1515R or 1517H families. If the machine has safety circuits, evaluate the safety architecture separately.

Q8: It is discontinued — can I still buy it, and how do I upgrade?

Yes. We supply stock units and tested refurbished spare parts and support exchange/repair services; please confirm stock and firmware version in advance. Replacement options: same-rating swap with 6ES7511-1AK02-0AB0 (150 KB / 1 MB, firmware and TIA version must match); capacity upgrade to the newer 6ES7511-1AL03-0AB0 (300 KB / 1.5 MB, requires a correspondingly recent TIA Portal); or step up to the 1513-1 PN / 1515-2 PN if the machine scope has grown. Changing the CPU type requires modifying the hardware configuration in TIA Portal, recompiling and downloading — verify in a test environment first.

Previous: 
Next: 

PRODUCTS

PRODUCTS

QUICK LINKS

CONTACT

+86-176-2073-4453
No. 858 Dujuan Road, Wangyue Subdistrict, Hunan Xiangjiang New Area,China
© 2026 Hunan Dream Road Electrical Technology Co., Ltd. All Rights Reserved. 
Privacy Policy            Sitemap