6ES7416-5HS06-0AB0
Siemens
| Availability: | |
|---|---|
| Quantity: | |
The CPU occupies a single slot in an S7-400 UR rack and is powered via the backplane bus (5 V typ. 1.6 A, typ. 7.5 W). Firmware version V6.0; engineering with STEP 7 V5.5 SP2 HF1 or higher (also integrates into PCS 7 process control systems). The MPI/DP interface serves programming, HMI networking and PROFIBUS DP master/slave communication; the independent DP interface and the PROFINET interface connect separate networks of distributed I/O and supervisory systems. In redundant mode, two CPUs are linked through the two sync module ports via fiber, synchronizing program and data status in real time; on failure, switchover is automatic and bumpless with zero impact on the process. The CPU supports CiR configuration in RUN, 2048 timers and counters, load memory expansion via FEPROM card (max. 64 MB) and battery-buffered data retention. It can also be configured as S7-400F for fail-safe operation (F programs with F-I/O modules), or used as a standalone high-performance S7-400 CPU.
16 MB work memory (6 MB program + 10 MB data), 0.03 µs bit operation — handles large PCS 7 projects with ease.
Dual CPUs synchronized over fiber with automatic bumpless switchover — eliminates single points of failure at controller level.
S7-400F/FH compatible: runs F safety programs with F-I/O modules, combining redundancy and safety in one system.
MPI/DP + DP + PROFINET + 2 sync module ports for parallel multi-network operation and flexible topologies.
CiR configuration in RUN plus hot-swappable memory card and battery — maintenance without stopping production.
Combined with redundant ET 200M slaves and redundant power supplies for complete controller-I/O-power redundancy.
Product type | SIMATIC S7-400H CPU 416-5H PN/DP (for S7-400H and S7-400F/FH) |
|---|---|
Work memory | 16 MB RAM (6 MB program + 10 MB data), not expandable |
Load memory | Onboard RAM max. 1 MB; FEPROM memory card max. 64 MB (flash card slot) |
Execution speed | Bit operation typ. 0.03 µs (30 ns) |
Interfaces | 5: 1 × MPI/DP, 1 × DP, 1 × PROFINET, 2 × sync module ports |
Redundancy | S7-400H hot standby: 2 identical CPUs + 2 sync modules + fiber; real-time synchronization, automatic bumpless switchover |
Fail safety | S7-400F/FH mode supported; F programs require F-I/O modules |
Timers / counters | 2048 each |
System functions | CiR, S7 communication, PG/OP communication, HMI services, diagnostic buffer, real-time clock (battery buffered) |
Engineering | STEP 7 V5.5 SP2 or higher (incl. HF1); integrates into PCS 7 process control systems |
Power supply | Backplane bus: 5 V DC typ. 1.6 A / max. 1.9 A; 24 V DC max. 150 mA (per DP interface); typ. 7.5 W |
Protection rating | IP20 (control cabinet installation only) |
Dimensions / weight | Standard S7-400 single-slot module (approx. 50 × 290 × 219 mm); net weight approx. 1.31 kg |
Lifecycle | PM300: Active (in production) |
Q1: What is the positioning of the CPU 416-5H compared to the 414-5H / 412-5H?
All are S7-400H redundant CPUs, tiered by performance and memory: CPU 412-5H (1 MB program + 1 MB data) → CPU 414-5H (4 MB + 4 MB) → CPU 416-5H (6 MB program + 10 MB data, this model). The 416-5H is the flagship for large PCS 7 projects and complex process units.
Q2: What components are needed to build a complete S7-400H redundant system?
You need: 2 identical CPUs (this item is a single unit), 2 sync modules (e.g. 6ES7960-1AA06-0XA0) with 1 m fiber cable, 2 UR racks with power supplies, and redundant ET 200M distributed I/O. Memory cards and backup batteries are ordered separately. Alternatively, choose the complete redundancy kits 6ES7400-0HR03-4AB0 / 0HR53-4AB0 (including dual CPUs, racks, power supplies and sync modules).
Q3: Can a single unit be used on its own?
Yes. The CPU can operate as a standard high-performance S7-400 CPU outside redundant mode; however, most projects deploy it in pairs, with the redundancy components (sync modules, fiber) configured separately.
Q4: How is the fail-safe (F) function implemented?
The CPU supports S7-400F/FH mode: with the F runtime license installed, F safety programs can be downloaded and safety-related I/O uses F-series modules (e.g. SM 326F). Safety and standard programs run in the same CPU, and redundancy (H) and safety (F) can be combined into an FH configuration.
Q5: Does the master/standby switchover affect production?
No. The two CPUs are synchronized in real time over fiber via the sync modules. If the master fails, the standby takes over automatically and bumplessly, without interrupting communication with distributed I/O or HMIs — zero disturbance to the process.
Q6: Which software is used for engineering?
Classic STEP 7 V5.5 SP2 HF1 or higher with LAD/FBD/STL/SCL/GRAPH; in PCS 7 environments, graphical CFC/SFC configuration is used — the mainstream solution in the process industries.
Q7: Are the memory card and battery included?
No. The FEPROM memory card for load memory and the backup battery for data retention are separate accessories and should be ordered together; the battery supports hot swapping.
Q8: What is the supply status of this model?
According to the official Siemens lifecycle status, the product is PM300 Active (in normal production) with stable availability. The S7-400H platform continues to serve both existing and new large continuous-production plants, ensuring reliable support for spares and expansion.