1747-L511

The 1747-L511 is the SLC 5/01 processor module in Rockwell Automation's Allen-Bradley SLC 500 programmable controller family — the entry-level CPU of this modular platform. A single slot houses the processor, 1K instructions of user memory and one DH-485 communication port; the module installs in slot 0 (far left) of a 1746 chassis and controls the discrete and analog I/O of the local and expanded chassis. The instruction set is based on the PLC-5 architecture and programmed with RSLogix 500, making it suitable for sequential control of small standalone machines, material handling, HVAC, water-treatment pump stations and simple process control. Thanks to its simple, rugged design, a large installed base remains in service in equipment commissioned more than a decade ago, and the model is a common item in the spare-parts market.
  • 1747-L511

  • AB

Availability:
Quantity:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
kakao sharing button
snapchat sharing button
telegram sharing button
sharethis sharing button

The processor must be installed in slot 0 of a 1746 chassis and occupies two slot widths. It communicates with I/O modules over the backplane and supports up to 3 local chassis with a total of 30 I/O module slots, a maximum of 960 local discrete I/O points and 480 analog points. Front-panel LEDs indicate RUN, CPU FAULT, FORCED I/O and BATTERY LOW for quick on-site status assessment. Program retention uses capacitor-backed RAM that holds the program for at least 30 minutes after power loss; an optional 1747-M1 (1K) or 1747-M2 (4K) EEPROM module provides permanent storage, or a lithium battery extends retention time. On the communication side there is one DH-485 port (19.2 kbps default) using RS-485 signalling, which can host an HMI, a programming workstation and other SLC nodes. Note that the SLC 5/01 can only receive and reply to messages from other nodes — it cannot initiate communication — and does not support Remote I/O topology, which is the key difference from higher models such as the 5/02 and 5/03. Backplane demand is only 90 mA @ 5 V DC (about 1.75 W), placing minimal load on the chassis power supply.

Entry-Level 1K Memory

1024 words of user program capacity — sufficient for sequential logic and interlocking on small machines.

Built-in DH-485

One DH-485 port for a small token-passing network with HMIs, programming PCs and other nodes.

3 Chassis / 30 Slots

Up to 3 local chassis and 30 I/O slots, with 960 discrete and 480 analog points.

Capacitor Backup

Capacitor-backed RAM retains the program for 30+ minutes; EEPROM or lithium battery optional.

Low Backplane Load

Only 90 mA @ 5 V DC (about 1.75 W) — no power-supply upgrade needed for replacement.

Visible Status

RUN / FAULT / FORCED I/O / BATTERY LOW LEDs make fault location straightforward.

Product type

Allen-Bradley SLC 500 processor module (SLC 5/01)

Catalog number

1747-L511 (series A / B / C)

User memory

1K instructions (1024 words), capacitor-backed RAM

Instruction set

Based on the PLC-5 instruction set with 52 programming instructions; approx. 4 µs per bit

Program scan time

8 ms per K instruction (typical)

I/O scan time

2.6 ms (typical)

Max. local I/O

960 discrete points; up to 480 analog points

Chassis / slots

Up to 3 local chassis with 30 I/O module slots in total

Communication port

1 × DH-485 (RS-485, 19.2 kbps default); reply-only, cannot initiate; no Remote I/O support

Memory backup

Capacitor backup (≥30 min); optional EEPROM 1747-M1 (1K) / 1747-M2 (4K); optional lithium battery

Backplane power

90 mA @ 5 V DC; approx. 1.75 W (6 BTU/hr)

Status indicators

RUN, CPU FAULT, FORCED I/O, BATTERY LOW

Installation

Slot 0 (far left) of a 1746 chassis; occupies two slot widths

Dimensions / weight

Approx. 51 × 152 × 152 mm; approx. 0.3 kg

Environment

Operating 0 to +60 °C; storage −40 to +85 °C; humidity 5%–95% non-condensing; vibration 2.5 G at 5–2000 Hz; shock 30 G

Programming software

RSLogix 500 (Studio 5000 is not supported)

Certifications

c-UL-us, CE, C-Tick; Class I, Division 2, Groups A/B/C/D

Lifecycle status

Discontinued (31 Jan 2017); now supplied as stock, refurbished or repair parts

Q1: What is the difference between the 1747-L511 and the 1747-L514?

Both are SLC 5/01 processors with identical instruction set, I/O capability and communication port. The only difference is user memory: 1K instructions for the L511 versus 4K for the L514. Choose the L514 if the program is large or likely to grow; the L511 is sufficient for spare-part replacement of small applications. Note that swapping one for the other still requires downloading the program.

Q2: Why can't it initiate communication with a host system?

The SLC 5/01's DH-485 port is designed to be "reply-only": it can receive commands from other nodes (HMI, programming PC, SCADA) and return responses, but cannot use MSG instructions to read or write other nodes on its own. If the application needs initiated messaging, Remote I/O or Ethernet, select an SLC 5/03 (1747-L532/L533), 5/04 (1747-L543/L544) or 5/05 (1747-L551/L552/L553).

Q3: What do I need to upload or download a program from a laptop?

You need a DH-485 interface converter (such as the 1747-UIC or a third-party USB-to-DH-485 adapter) plus RSLogix 500 software — a laptop's built-in RS-232/serial port cannot connect directly to DH-485. This is the most common pitfall after replacing a processor: the module is fine, but the adapter and the backup program are missing.

Q4: Is the program lost when power is removed?

Not immediately. The SLC 5/01 uses capacitor-backed RAM that holds the program for at least 30 minutes, so short outages or battery changes are not a problem. For long-term security, add an EEPROM module (1747-M1 1K / 1747-M2 4K) to store the program permanently, or fit a lithium battery to extend retention time.

Q5: Is this model still available, and what is the supply situation?

The 1747-L511 was officially discontinued by Rockwell Automation on January 31, 2017; the market now offers new old stock, refurbished units and repair services. We can supply tested stock and refurbished modules and support exchange/repair of failed units. For batch projects, confirm inventory and lead time early to avoid line-down risk.

Q6: How many I/O modules can it carry? Can it drive remote drops?

Up to 3 local chassis with 30 I/O module slots in total, and a maximum of 960 discrete / 480 analog points. The SLC 5/01 does not support Remote I/O; chassis are linked with local expansion cables such as 1746-C7/C9, which limits distances (typically within the same control cabinet). Distributed I/O over distance requires an SLC 5/02 or higher.

Q7: Can it be programmed with Studio 5000?

No. The SLC 500 family is programmed with RSLogix 500 (now maintained by Rockwell as legacy software); Studio 5000 Logix Designer supports only Logix platforms such as ControlLogix and CompactLogix. If only Studio 5000 is available, an RSLogix 500 installation and license must be arranged separately.

Q8: Is it still worth using in new projects? What are the alternatives?

It is not recommended for new projects — 1K memory, reply-only DH-485 communication and no Ethernet fall far short of today's data-acquisition and connectivity requirements. For new builds, consider the CompactLogix 5380 (5069 platform with integrated EtherNet/IP) or the Micro850/Micro870 (economical option for small standalone machines). For a complete SLC 500 modernization, we can provide an I/O migration and program-conversion assessment.