6ES7960-1AA06-0XA0
Siemens
| Availability: | |
|---|---|
| Quantity: | |
Each CPU 41xH provides two reserved synchronization interfaces and requires two synchronization modules; a complete S7-400H redundant system (dual CPUs) therefore requires four synchronization modules in total, with the two CPUs interconnected via two fiber-optic cables to form a redundant two-channel synchronization link. The module is supplied with 3.3 V directly from the CPU, drawing a maximum of 220 mA with a typical power loss of just 0.77 W, and its ultra-compact 13 × 14 × 58 mm footprint occupies no rack slot. The short-distance version uses 850 nm optical transceivers, permits a maximum fiber attenuation of 7.5 dB and a maximum cable length difference of 9 m, and connects via standard fiber-optic patch cables; the matching fiber-optic connecting cables (6ES7961 series) must be ordered separately according to the actual distance. The module operates at ambient temperatures up to 60 °C and complies with EU directives including ATEX (explosion protection), EMC and RoHS.
Fiber-optic patch cables over up to 10 m — the standard solution for redundant systems in one or adjacent cabinets.
Plugs straight into the reserved synchronization slot of CPU 41xH — no wiring, no rack slot used.
2 modules per CPU and 2 fiber cables make the synchronization link itself redundant.
13 × 14 × 58 mm, 0.77 W typical power loss, powered at 3.3 V directly by the CPU.
Short-range wavelength with 7.5 dB permissible attenuation — standard patch cables, plug and play.
Operation up to 60 °C; compliant with ATEX, EMC and RoHS EU directives.
Product type | SIMATIC S7-400H synchronization module V6, short-distance version (for S7-400H/F/FH) |
|---|---|
Application | Coupling of CPU 41xH (plugs directly into the reserved CPU sync slot) |
Max. cable length between CPUs | 10 m (fiber-optic patch cable) |
Transceiver wavelength | 850 nm (short-distance; the 10 km long-distance version 1AB06 uses 1310 nm) |
Permissible fiber attenuation | Max. 7.5 dB |
Permissible cable length difference | Max. 9 m |
Supply voltage | 3.3 V, supplied by the CPU |
Current consumption | Max. 220 mA |
Power loss | Typ. 0.77 W |
Quantity required | 2 per CPU; 4 in total per dual-CPU redundant system + fiber patch cables |
Ambient temperature | Operation up to +60 °C |
Dimensions / weight | 13 × 14 × 58 mm (W × H × D); approx. 14 g |
Identification | Black interlock clips (distinguishes it from the blue clips of the 10 km version) |
Compliance | ATEX (2014/34/EU), EMC (2014/30/EU), RoHS (2011/65/EU) |
Q1: What role does the synchronization module play in an S7-400H redundant system?
It is the "heartbeat" channel between the two redundant CPUs: programs, process data and status information are synchronized in real time over fiber optics, keeping the standby CPU always consistent with the master. Without synchronization modules, the S7-400H cannot perform bumpless hot-standby switchover.
Q2: How many synchronization modules does a redundant system need?
Each CPU 41xH requires 2 synchronization modules, so a complete dual-CPU redundant system needs 4 modules in total, plus 2 fiber-optic patch cables (6ES7961 series) to form the redundant two-channel synchronization link.
Q3: What is the difference between this module (1AA06) and the long-distance version (1AB06)?
The versions and installation are identical; only distance and wavelength differ: this 1AA06 is the short-distance version with fiber patch cables up to 10 m, 850 nm wavelength, 7.5 dB permissible attenuation and black interlock clips. The 1AB06 long-distance version reaches up to 10 km at 1310 nm with 9.5 dB permissible attenuation and blue interlock clips. Choose according to the actual distance between the two CPUs — this module is sufficient for the same or adjacent cabinets; the long-distance version is only needed across buildings or plant sections.
Q4: Do the fiber-optic cables need to be purchased separately?
Yes. The synchronization module does not include fiber cables. Order Siemens dedicated synchronization fiber-optic cables (6ES7961 series, patch cable type) according to the actual distance, observing a maximum length difference of 9 m between the two cables and a total attenuation of no more than 7.5 dB.
Q5: Is installation complicated?
Not at all. Simply plug the module into the reserved synchronization slot on the CPU and lock it — no wiring and no rack I/O slot required. Connect the fiber patch cable and the module is ready for use.
Q6: What if the two cabinets are more than 10 m apart?
Use the long-distance synchronization module 6ES7960-1AB06-0XA0 (blue interlock clips) instead. Together with routed installation fiber-optic cables it supports distances of up to 10 km, covering redundant installations across control rooms, buildings or plant sections.
Q7: Does a fault in the synchronization link affect production?
The synchronization link is a two-channel design (2 modules and 2 fibers per CPU). If a single fiber or module fails, the redundant system keeps running and raises an alarm, but the fault should be repaired promptly to restore full redundancy protection.
Q8: What are the environmental requirements?
The module is powered at 3.3 V directly by the CPU and needs no external supply. It operates at ambient temperatures up to +60 °C, measures only 13 × 14 × 58 mm, is mounted on the CPU front panel, and complies with the ATEX, EMC and RoHS EU directives.