6ES7403-1JA01-0AA0
Siemens
| Availability: | |
|---|---|
| Quantity: | |
The ER2 is a passive backplane rack connected to the central rack via a send IM 460 interface module in the central rack and a receive IM 461 in the expansion rack, extending the I/O capacity of the S7-400 to remote or separate cabinets. Since it carries only the P bus (no K bus), the rack supports signal-module data exchange only: DI/DO and AI/AO modules work plug-and-play, while function modules (FM) and communication processors (CP) — which rely on the K bus to talk to the CPU — cannot be used. The rack also provides no interrupt line and no 24 V backplane supply; if a battery is fitted, battery monitoring must be switched off. As a pure expansion rack it cannot host a CPU or serve as a central rack, but it works perfectly as a distributed I/O expansion rack in S7-400H redundant projects. For larger expansion needs, choose the 18-slot ER1; a lightweight aluminum version with identical functionality is available as 6ES7403-1JA11-0AA0.
A low-cost expansion platform designed exclusively for signal modules — plug-and-play I/O extension.
Space for 2 PS405/PS407 power supplies enables redundant power for higher availability.
Durable steel rack, only 257.5 mm wide — saves space in expansion cabinets.
Connects to the central rack via standard interface modules, smoothly extending S7-400 I/O capacity.
0 to +60 °C operation, certified to CE/UL/FM/KC/EAC/CCC and more.
An aluminum version with identical functionality (6ES7403-1JA11-0AA0) is available for reduced weight.
Product type | SIMATIC S7-400 expansion rack ER2 (9 slots, for signal modules only) |
|---|---|
Number of slots | 9 (including slots for the receive interface module IM 461 and power supply) |
Bus configuration | P bus (I/O bus) only; no communication bus (K bus), no interrupt line |
Supported modules | Signal modules (SM: DI/DO/AI/AO) only; no CPU, FM or CP |
Power configuration | Accepts 2 PS405 / PS407 power supplies, supporting redundant power |
Interconnection | Send IM 460 (central rack) + receive IM 461 (this rack) |
Backplane supply | No 24 V auxiliary backplane supply; no battery backup support (disable battery monitoring) |
Material | Steel base plate (aluminum lightweight version: 6ES7403-1JA11-0AA0) |
Ambient conditions | Operating 0 to +60 °C; storage/transport 0 to +70 °C |
Dimensions | 257.5 × 290 × 27.5 mm (W × H × D) |
Weight | Approx. 2.2 kg |
Protection rating | IP20 (control cabinet installation only) |
Certifications | CE, UKCA, UL, FM, RCM, KC, EAC, CCC; marine approvals (NK, CCS) |
Lifecycle | PM300: Active |
Q1: What is the difference between ER2 and UR1/UR2 universal racks?
UR1/UR2 are universal racks that host CPUs, FMs, CPs and all other modules, usable as central or expansion racks. ER2 is a function-reduced expansion rack — P bus only, signal modules only — at lower cost, dedicated to I/O expansion and not usable as a central rack.
Q2: Which modules can be installed in the ER2?
Only signal modules (SM), such as digital and analog I/O modules. Since the rack has no K bus, function modules (FM) and communication processors (CP) cannot exchange data with the CPU even if inserted; there is also no interrupt line, so SM hardware interrupts are not transmitted. Select it strictly for pure I/O extension.
Q3: How is the ER2 connected to the central rack?
Interface modules are used in pairs: a send IM (e.g. IM 460-0/460-1) in the central rack and a receive IM (e.g. IM 461-0/461-1) in the ER2, connected by cable. Depending on the IM type chosen, distances of up to several hundred meters are possible.
Q4: What power supply does the rack need?
The expansion rack requires its own system power: 1–2 PS405 (DC input) or PS407 (AC input) modules can be fitted; two of them provide redundant power. Note that the ER2 backplane provides no 24 V auxiliary supply.
Q5: Why does a battery fault appear after installing a battery?
The ER2 does not support the battery backup line; after fitting a battery in the power supply, battery monitoring must be switched off, otherwise the system reports a battery fault. Rely on the central rack side for CPU data backup.
Q6: Should I choose ER1 or ER2?
Choose by the number of I/O modules: the ER2 offers 9 slots in a compact size for small expansion stations, while the ER1 (6ES7403-1TA01-0AA0 steel / 1TA11 aluminum) offers 18 slots for large-scale I/O expansion. Their functional positioning is identical.
Q7: Can it be used in an S7-400H redundant system?
Yes — but only as a distributed I/O expansion rack within a redundant project (redundant power supplies are recommended). The ER2 cannot host CPUs and must not be used as the dual-CPU redundant central rack of S7-400H (that requires a UR2-H, 6ES7400-2JA00-0AA0).
Q8: How do I choose between the steel and aluminum versions?
This model (1JA01) has a steel base plate — strong and cost-effective; the identical 1JA11 (6ES7403-1JA11-0AA0) uses aluminum for reduced weight. Functionality is the same; choose by load and cost preferences.