The 6ES7331-7KB02-0AB0 is a SIMATIC S7-300 SM 331 analog input module featuring 2 channels with programmable resolution of 9, 12, or 14 bits. It supports voltage, current, thermocouple, and resistance inputs, making it a versatile choice for compact analog measurement applications.

The module includes diagnostic and alarm functions and requires a 20-pin front connector (not included). Note that when configured for resistance or RTD measurement, only the first channel is available; the second channel can only be used for current measurement.

Product Lifecycle: PM410 (Product Cancellation). Every unit is 100% tested before dispatch to ensure reliable operation in your existing S7-300 system.
  • 6ES7331-7KB02-0AB0

  • Siemens

Availability:
Quantity:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
kakao sharing button
snapchat sharing button
telegram sharing button
sharethis sharing button
The 6ES7331-7KB02-0AB0 is an analog input module from the SIMATIC S7-300 family, specifically the SM 331 series. It provides 2 analog input channels organized in 1 channel group, with programmable resolution of 9, 12, or 14 bits.

Supported input types include voltage (±1V, ±2.5V, ±5V, ±10V, 1-5V, ±250mV, ±500mV), current (0-20mA, ±3.2mA, ±10mA, ±20mA, 4-20mA), thermocouples (E, J, K, L, N), and resistance/RTD (Pt100, Ni100, 0-150Ω, 0-300Ω, 0-600Ω).

Important Limitation: When configured for resistance or RTD measurement, only the first channel (channel 0) is functional. The second channel can only be used for current measurement, and its default value is overflow (7FFFH) when not used.

Configuration Note: The module has measuring range modules (positions A/B/C/D) on the side. These must match the sensor type: A for RTD/thermocouple, B for voltage, C for 4-wire current, D for 2-wire current.

Product Lifecycle: PM410 (Product Cancellation, effective October 2025). We guarantee 100% functional testing before shipping for maintenance or spare parts inventory.
• 2 Analog Inputs: 1 channel group, programmable resolution 9/12/14 bits.
• Universal Input Types: Voltage, current, thermocouple (E/J/K/L/N), RTD (Pt100/Ni100) and resistance.
• Diagnostic & Alarm: Parameterizable diagnostics and limit value monitoring.
• Measuring Range Modules: Side selector (A/B/C/D) for sensor matching.
• RTD Limitation: Only channel 0 works for resistance/RTD measurement; channel 1 is current-only.
• 20-Pin Connector: Requires a 20-pin front connector (not included).
• 100% Tested: Every module undergoes rigorous functional testing before dispatch.
• Ready to Ship: Stock available for fast global delivery.
General Information:
• Product Type: SM 331, AI 2 x 9/12/14 Bit
• Number of Analog Inputs: 2 (1 channel group)
• Number of Resistance Inputs: 1 (channel 0 only)
• Resolution: 9/12/14 bits (programmable)
• Required Front Connector: 20-pin (not included)
• Isolation: Optically isolated from backplane bus

Input Ranges (Voltage):
• 1-5V, ±1V, ±2.5V, ±5V, ±10V, ±250mV, ±500mV
• Input Resistance: 100 kΩ (most ranges); 10 MΩ (±1V, ±250mV)

Input Ranges (Current):
• 0-20mA, ±3.2mA, ±10mA, ±20mA, 4-20mA
• Input Resistance: 25 Ω
• Supported: 2-wire and 4-wire

Input Ranges (Thermocouple):
• Types: E, J, K, L, N

Input Ranges (RTD/Resistance):
• Pt100, Ni100 (standard and climatic)
• Resistance: 0-150Ω, 0-300Ω, 0-600Ω
• Note: Only channel 0 available for resistance measurement

Power Supply:
• Load Voltage L+ (rated): 24V DC
• Current from Backplane Bus 5V DC (max): 50 mA
• Power Loss (typical): 1 W

Isolation & Protection:
• Permissible Input Voltage (destruction limit): 20V continuous; 75V for max. 1s
• Permissible Input Current (destruction limit): 40 mA
• Protection Class: IP20

Mechanical Data:
• Dimensions (W x H x D): 40 x 125 x 117 mm
• Weight (approx.): 250 g

Product Lifecycle: PM410 (Product Cancellation)
Q: Can I use both channels for PT100 sensors?
A: No. When configured for resistance or RTD measurement, only channel 0 is functional. Channel 1 can only be used for current measurement. If you need two RTD inputs, please choose a different module (e.g., 6ES7331-7KF02-0AB0 with 8 channels).

Q: Can this module connect to a 2-wire transmitter?
A: Yes. Set the measuring range module to position "D" for 2-wire current, or "C" for 4-wire current.

Q: What is the function of the measuring range modules on the side?
A: The 4 positions (A/B/C/D) select the input type: A for RTD/thermocouple/resistance, B for voltage, C for 4-wire current, D for 2-wire current. They must match the hardware configuration.

Q: What front connector is required?
A: This module requires a 20-pin front connector (not included). Please order separately.

Q: Is this product still in production?
A: No. This module is in PM410 lifecycle status (Product Cancellation, effective October 2025). It is primarily intended for maintenance and spare parts replacement. Please verify availability before ordering for new projects.

Q: Is this product tested?
A: Yes. We supply tested units that are 100% functionally verified before dispatch. Contact us for current stock and shipping rates.