6ES7231-7PB22-0XA8

The 6ES7231-7PB22-0XA8 (EM231 RTD) is an RTD analog input module of the Siemens SIMATIC S7-200 CN family, providing 2 RTD temperature input channels. It connects directly to Pt100, Pt1000, Ni100 and Ni1000 resistance temperature sensors, so temperature can be measured without an external temperature transmitter. It is widely used for temperature monitoring in furnaces, ovens, injection molding machines, constant-temperature equipment and water treatment systems.
  • 6ES7231-7PB22-0XA8

  • Siemens

Availability:
Quantity:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
kakao sharing button
snapchat sharing button
telegram sharing button
sharethis sharing button

DIP switches on the side of the module are used to select the sensor type, temperature unit (°C / °F) and wiring method, so different field sensors can be adapted without complex configuration. The measured temperature is stored as a 16-bit value in the CPU's analog input word (AIW) in units of 0.1 °C (or 0.1 °F), ready for comparison, calculation, PID control and display on a host system.

The module supports 2-wire and 3-wire RTD wiring; the 3-wire connection compensates for lead resistance and improves measurement accuracy over long cable runs. It connects to the S7-200 CN CPU or the previous expansion module via the backplane bus, mounts on a standard DIN rail, and is automatically recognized with channel addresses assigned by the system — allowing flexible multi-channel temperature acquisition systems to be built together with the CPU and other modules.

  • 2 RTD inputs: connect RTD sensors directly and eliminate temperature transmitters, reducing system cost and wiring effort.

  • Wide sensor support: Pt100, Pt1000, Ni100, Ni1000 and resistance input, selectable via DIP switches.

  • High resolution: 15 bits + sign, with temperature output in 0.1 °C units for typical industrial accuracy requirements.

  • 2-wire / 3-wire wiring: 3-wire connection compensates lead resistance for better accuracy on long runs.

  • Plug and play: connects directly to the CPU via the backplane bus; channel addresses assigned automatically, no separate configuration.

  • Easy installation: standard DIN rail mounting, compact design, fits side by side with other S7-200 CN modules.

Part Number

6ES7231-7PB22-0XA8 (EM231 RTD, 2 channels)

Module Type

S7-200 CN analog input module (RTD type)

Number of Inputs

2 channels

Supported Sensors

Pt100, Pt1000, Ni100, Ni1000 RTDs (plus resistance input), selected by DIP switch

Resolution

15 bits + sign

Data Format

16-bit integer, temperature in units of 0.1 °C / 0.1 °F

Typical Measuring Range

Pt100 / Pt1000: -200 to 850 °C; Ni100: -60 to 180 °C; Ni1000: -50 to 150 °C

Wiring

2-wire / 3-wire (3-wire compensates lead resistance)

Channel Isolation

Not isolated between channels

Power Supply

Supplied by the CPU via the backplane bus (5V DC)

Dimensions

Approx. 46 mm × 80 mm × 62 mm

Mounting

Standard DIN rail

Protection / Operating Temperature

IP20; 0–55 °C

Compatible CPUs

S7-200 CN series: CPU 221 / 222 / 224 / 224 XP / 226

Q1: Which temperature sensors can this module accept?

A: The EM231 RTD supports Pt100, Pt1000, Ni100 and Ni1000 resistance sensors, plus a resistance input mode selected by DIP switch. It cannot accept thermocouples — for thermocouples use the EM231 TC module (6ES7231-7PD22-0XA8).

Q2: Do I still need a temperature transmitter?

A: No. The module includes the RTD excitation and linearization circuitry, so sensors connect directly to the module terminals — simpler wiring and lower cost. Keep sensor leads as short as possible and away from power cables to minimize interference.

Q3: Should I use 2-wire or 3-wire wiring?

A: Use 2-wire when the sensor is close to the module and moderate accuracy is acceptable; for long cable runs or higher accuracy, use 3-wire to compensate lead resistance. Refer to the wiring diagram on the side of the module.

Q4: Does the module need configuration? How are values read?

A: Sensor type and range are set with DIP switches on the module — no software configuration is needed. Read the corresponding analog input word (AIW) directly; the value is in 0.1 °C units (e.g. 253 means 25.3 °C).

Q5: Can this module be used with the S7-200 SMART?

A: No. The EM231 series is dedicated to the S7-200 / S7-200 CN and is not compatible with the S7-200 SMART expansion interface. For the S7-200 SMART, use its dedicated RTD/analog expansion modules.

Previous: 
Next: 

PRODUCTS

PRODUCTS

QUICK LINKS

CONTACT

+86-176-2073-4453
No. 858 Dujuan Road, Wangyue Subdistrict, Hunan Xiangjiang New Area,China
© 2026 Hunan Dream Road Electrical Technology Co., Ltd. All Rights Reserved. 
Privacy Policy            Sitemap