6ES7231-7PB22-0XA8
Siemens
| Availability: | |
|---|---|
| Quantity: | |
DIP switches on the side of the module are used to select the sensor type, temperature unit (°C / °F) and wiring method, so different field sensors can be adapted without complex configuration. The measured temperature is stored as a 16-bit value in the CPU's analog input word (AIW) in units of 0.1 °C (or 0.1 °F), ready for comparison, calculation, PID control and display on a host system.
The module supports 2-wire and 3-wire RTD wiring; the 3-wire connection compensates for lead resistance and improves measurement accuracy over long cable runs. It connects to the S7-200 CN CPU or the previous expansion module via the backplane bus, mounts on a standard DIN rail, and is automatically recognized with channel addresses assigned by the system — allowing flexible multi-channel temperature acquisition systems to be built together with the CPU and other modules.
2 RTD inputs: connect RTD sensors directly and eliminate temperature transmitters, reducing system cost and wiring effort.
Wide sensor support: Pt100, Pt1000, Ni100, Ni1000 and resistance input, selectable via DIP switches.
High resolution: 15 bits + sign, with temperature output in 0.1 °C units for typical industrial accuracy requirements.
2-wire / 3-wire wiring: 3-wire connection compensates lead resistance for better accuracy on long runs.
Plug and play: connects directly to the CPU via the backplane bus; channel addresses assigned automatically, no separate configuration.
Easy installation: standard DIN rail mounting, compact design, fits side by side with other S7-200 CN modules.
Part Number | 6ES7231-7PB22-0XA8 (EM231 RTD, 2 channels) |
|---|---|
Module Type | S7-200 CN analog input module (RTD type) |
Number of Inputs | 2 channels |
Supported Sensors | Pt100, Pt1000, Ni100, Ni1000 RTDs (plus resistance input), selected by DIP switch |
Resolution | 15 bits + sign |
Data Format | 16-bit integer, temperature in units of 0.1 °C / 0.1 °F |
Typical Measuring Range | Pt100 / Pt1000: -200 to 850 °C; Ni100: -60 to 180 °C; Ni1000: -50 to 150 °C |
Wiring | 2-wire / 3-wire (3-wire compensates lead resistance) |
Channel Isolation | Not isolated between channels |
Power Supply | Supplied by the CPU via the backplane bus (5V DC) |
Dimensions | Approx. 46 mm × 80 mm × 62 mm |
Mounting | Standard DIN rail |
Protection / Operating Temperature | IP20; 0–55 °C |
Compatible CPUs | S7-200 CN series: CPU 221 / 222 / 224 / 224 XP / 226 |
Q1: Which temperature sensors can this module accept?
A: The EM231 RTD supports Pt100, Pt1000, Ni100 and Ni1000 resistance sensors, plus a resistance input mode selected by DIP switch. It cannot accept thermocouples — for thermocouples use the EM231 TC module (6ES7231-7PD22-0XA8).
Q2: Do I still need a temperature transmitter?
A: No. The module includes the RTD excitation and linearization circuitry, so sensors connect directly to the module terminals — simpler wiring and lower cost. Keep sensor leads as short as possible and away from power cables to minimize interference.
Q3: Should I use 2-wire or 3-wire wiring?
A: Use 2-wire when the sensor is close to the module and moderate accuracy is acceptable; for long cable runs or higher accuracy, use 3-wire to compensate lead resistance. Refer to the wiring diagram on the side of the module.
Q4: Does the module need configuration? How are values read?
A: Sensor type and range are set with DIP switches on the module — no software configuration is needed. Read the corresponding analog input word (AIW) directly; the value is in 0.1 °C units (e.g. 253 means 25.3 °C).
Q5: Can this module be used with the S7-200 SMART?
A: No. The EM231 series is dedicated to the S7-200 / S7-200 CN and is not compatible with the S7-200 SMART expansion interface. For the S7-200 SMART, use its dedicated RTD/analog expansion modules.