5069-L320ER
AB
| Availability: | |
|---|---|
| Quantity: | |
The two Gigabit Ethernet ports can be used in three ways: a Device Level Ring (DLR), linear/star topologies, or Dual-IP mode with Studio 5000 version 29 or later, which physically separates machine-level I/O traffic from the plant management network without an additional switch. The controller provides 32 sockets and up to 32 tasks (1,000 programs per task) for modular program organization at medium scale. Power is supplied through separate MOD Power and SA Power inputs: MOD side 18–32 V DC (450 mA max, 850 mA inrush for 125 ms); SA side 0–32 V DC or 0–240 V AC (47–63 Hz, limited to 125 V AC in ATEX/IECEx environments); both pass through up to 10 A, so controller logic power and field sensor/actuator power can be kept separate to suppress field noise and short-circuit effects. The controller is battery-free — the program and firmware reside on the supplied 2 GB SD card (1784-SD2), expandable to 32 GB. Maximum power dissipation is 8.5 W (29 BTU/hr), isolation to the backplane is 300 V continuous (no isolation between the two Ethernet ports), operating temperature is 0–60 °C, and the IP20 open-style housing must be installed inside a control cabinet.
2 × 1 Gbps full duplex with DLR ring, linear/star and dual-IP modes for redundant or segmented networks.
2 MB user memory and a quad-core processor for small to mid-size high-speed machines and medium-complexity programs.
Expand directly with up to 16 Compact 5000 I/O modules — digital, analog and specialty functions.
Connect drives, remote I/O, HMIs and smart devices in a machine-level integrated architecture.
Independent logic and field power inputs, each rated 10 A passthrough, for noise immunity and zoned shutdown.
No battery; the supplied 2 GB SD card holds program and firmware, so a replacement unit is restored by simply inserting the card.
Product type | Allen-Bradley CompactLogix 5380 programmable automation controller (PAC) |
|---|---|
Catalog No. / UPC | 5069-L320ER / 889508071251 |
User memory | 2 MB |
Nonvolatile storage | 2 GB SD card supplied (1784-SD2), expandable to 32 GB (1784-SDHC32) |
Processor | Quad-core |
Communication ports | 2 × 10/100/1000 Mbps Ethernet (full duplex); 1 × USB 2.0 Type B (12 Mbps) |
Network topologies | DLR, linear, star; dual-IP mode (Studio 5000 v29 or later) |
EtherNet/IP nodes | Up to 40 devices; up to 32 sockets |
Local I/O expansion | Up to 16 Compact 5000 I/O modules (1769 series not supported) |
Motion control | 0 axes (standard model; choose 5069-L320ERM with 8 axes for integrated motion) |
Tasks / programs | Up to 32 tasks, up to 1,000 programs per task |
MOD power | 18–32 V DC, 450 mA max; inrush 850 mA for 125 ms; passthrough 9.55 A |
SA power | 0–32 V DC or 0–240 V AC (47–63 Hz; 125 V AC max in ATEX/IECEx); 10 mA max (DC) / 25 mA (AC); passthrough 9.95 A |
Power dissipation / heat | 8.5 W max / 29 BTU·hr⁻¹ |
Isolation | 300 V continuous; no isolation between the two Ethernet ports |
Mounting | DIN rail, horizontal only; IP20 open style (cabinet required) |
Dimensions / weight | 143.97 × 98.10 × 136.81 mm (H × W × D); approx. 0.768 kg |
Environment | Operating 0 to +60 °C; storage −40 to +85 °C; humidity 5%–95% non-condensing; vibration 5 m/s² (5–500 Hz); shock 30 g |
Programming software | Studio 5000 Logix Designer v28 or later |
Certifications | CE, c-UL-us, CCC, RCM, ATEX, IECEx, EAC, RINA (marine), among others — see product label |
Lifecycle status | Active (repairable / replaceable) |
Q1: What is the difference between the 5069-L320ER and the 5069-L320ERM?
Memory, ports, I/O expansion and node count are identical; the decisive difference is motion capability. The L320ER has 0 axes and handles logic, process and standard I/O control only, while the L320ERM provides integrated motion on EtherNet/IP for up to 8 CIP drive axes. If the machine needs synchronized servo or positioning motion, select the M version.
Q2: Is 2 MB enough, and how does it compare with the L330ER/L340ER?
2 MB suits medium-complexity machine programs (several thousand ladder rungs, multiple AOIs and recipe management). For larger programs, extensive trending/recipes or future headroom, consider the 5069-L330ER (3 MB) or 5069-L340ER (4 MB). All three share the same ports and I/O expansion; they differ mainly in memory and node count (40 / 60 / 90).
Q3: Can existing 1769 Compact I/O modules still be used?
No. The 5069 controller uses the new Compact 5000 I/O backplane architecture and supports only 5069 Compact I/O modules — the 1769 series is incompatible both electrically and mechanically. When migrating from an L3x/1769 system, the I/O modules and terminal blocks must be replaced as well; review the I/O list before starting the retrofit.
Q4: What is the best way to use the two Ethernet ports?
There are two common approaches: (1) DLR ring — both ports join a ring so the network self-heals on a single break, ideal for daisy-chained machine layouts; (2) dual-IP mode (Studio 5000 v29 or later) — assign different subnets to each port, one for machine-level devices and one for the plant network, achieving physical separation without extra routing hardware. Note that the two ports are not isolated from each other; only 300 V isolation to the backplane is provided.
Q5: Do the 40 EtherNet/IP nodes include HMIs and drives?
Yes. The node count reflects the total EtherNet/IP connections the controller can establish, including HMIs, drives, remote I/O adapters and smart valve manifolds. We recommend keeping 20%–30% headroom in real projects, and considering network load and RPI settings for their effect on scan time.
Q6: Where is the program stored? Must it be re-downloaded when replacing the controller?
The controller is battery-free and stores the program and firmware on the SD card (the supplied 2 GB 1784-SD2). When replacing a controller of the same model, insert the original SD card into the new unit to restore the program and firmware without re-downloading; the card can also hold project backups.
Q7: Which software version is required? Can it perform safety control?
Use Studio 5000 Logix Designer v28 or later (dual-IP mode requires v29 or later). This is a standard controller without safety functions; for SIL 2/PL d or SIL 3/PL e safety control, choose the Compact GuardLogix 5380 family (e.g. 5069-L320ERMS2 / 5069-L320ERMS3).
Q8: What should be noted for installation and power wiring?
Mount horizontally on a DIN rail with clearance above and below for cooling, inside an IP20 control cabinet only. Both MOD Power (18–32 V DC) and SA Power (AC or DC) must be wired — the system will not operate if either is missing, and neither terminal block may exceed 10 A. Use the 5069-RTB64-SCREW or 5069-RTB64-SPRING terminal kit (ordered separately).