The module connects directly to the LOGO! 8 base module via the internal system bus, is recognized automatically with plug-and-play simplicity, and provides galvanic isolation between the bus and field side. The 4 AC/DC-type digital inputs acquire 115/230 V level signals (phase-line switches, buttons, auxiliary contacts) directly, eliminating intermediate conversion relays; the 4 relay outputs are galvanically isolated dry contacts rated 5 A resistive / 3 A inductive per contact with lamp loads up to 1000 W, suitable for AC and DC loads alike. At only 36 mm wide (2 module units), the module clips onto a 35 mm DIN rail, offers IP20 protection, operates from 0 to +55 °C, and holds VDE 0631, CSA, UL and FM approvals per IEC 61131 — usable in residential areas.
8-Point I/O Expansion4 digital inputs + 4 relay outputs — 8 I/O points in a compact module
Mains-Level Inputs115~230 V AC/DC input levels connect phase-line switching signals directly — no conversion relays
Wide Supply Range85~265 V AC / 100~253 V DC — plugs into grid voltages worldwide
Relay OutputsIsolated dry contacts: 5 A resistive / 3 A inductive / 1000 W lamp load, AC or DC
Galvanic IsolationIsolation between system bus and field side for strong interference immunity
Ultra-Narrow BodyOnly 36 mm wide (2 module units) — the most space-saving LOGO! digital expansion
Model | 6ED1055-1FB00-0BA2 (LOGO! DM8 230R expansion module) |
|---|---|
Compatible with | LOGO! 8 and higher versions (requires a LOGO! base module) |
Supply voltage | 115 ~ 230 V AC/DC; permissible range AC 85 ~ 265 V, DC 100 ~ 253 V; 47 ~ 63 Hz |
Bus power consumption | From system bus 5 V: 30 mA |
Digital inputs | 4 DI, AC/DC type (115/230 V level) |
Input current / delay | Signal "1" typ. 0.13 mA (DC) / 0.08 mA (AC); 0→1 max. 40 ms, 1→0 max. 75 ms |
Digital outputs | 4 relay outputs (DO), galvanically isolated dry contacts |
Switching capacity | Max. 5 A per contact (resistive); 3 A inductive; lamp load max. 1000 W; switching frequency 2 Hz resistive / 0.5 Hz inductive |
Short-circuit protection | Relay outputs not short-circuit protected internally (configure external fuses per load) |
Galvanic isolation | Between system bus and field side |
Mounting | 35 mm standard DIN rail, 2 module units wide |
Dimensions | 36 mm (W) × 90 mm (H) × 58 mm (D) |
Protection rating | IP20 |
Ambient temperature | Operation 0 ~ +55 °C |
EMC | EN 55011 limit class B (for use in residential areas) |
Approvals | VDE 0631, CSA, UL, FM, marine approvals; developed per IEC 61131; UKCA |
Q1: What is the 6ED1055-1FB00-0BA2?
It is the Siemens LOGO! DM8 230R digital expansion module. Used with a LOGO! 8 series base module, it adds 4 digital inputs (115/230 V AC/DC levels) and 4 relay outputs to expand the I/O capacity of the LOGO! control system.
Q2: How does the DM8 230R differ from the DM16 230R / DM16 24R?
The DM8 230R (this model) offers 4 DI + 4 DO with mains-level AC/DC inputs, 36 mm wide. The DM16 230R (6ED1055-1FB10-0BA2) offers 8 DI + 8 DO at 71.5 mm wide. The DM16 24R (6ED1055-1NB10-0BA2) uses 24 V DC input levels. In short: choose DM8 for fewer points and DM16 for more; choose 230R for 230 V field signals and 24R for 24 V signals.
Q3: Can it connect 230 V mains switching signals directly?
Yes. The 4 inputs are AC/DC-type, designed for 115/230 V AC or DC levels. Switches, buttons and auxiliary contacts on the phase line can be wired directly — no intermediate level-conversion relays required. This is the key advantage over 24 V input modules.
Q4: What loads can the relay outputs drive?
Each relay output is a galvanically isolated dry contact rated max. 5 A resistive and 3 A inductive, with lamp loads up to 1000 W — driving contactor coils, solenoid valves, signal lamps and small heaters (AC or DC) directly. Relay outputs have no built-in short-circuit protection; configure external fuses as required, and add surge suppression for frequent switching of inductive loads.
Q5: What are the supply requirements?
The module is supplied from 115~230 V AC or DC (permissible range AC 85~265 V, DC 100~253 V, 47~63 Hz). It accepts the main grid voltages used worldwide — simply keep the supply scheme consistent with the connected LOGO! base module.
Q6: How is the module installed?
It clips directly onto a 35 mm standard DIN rail, occupying only 2 module units of width (36 mm) — the most space-saving LOGO! digital expansion module. With IP20 protection, install it inside a control cabinet or wiring box; operating temperature range is 0 ~ +55 °C.
Q7: What are typical applications?
Typical applications are small automation and building services scenarios based on 230 V control circuits, such as lighting and blinds control, pump and fan control, gate systems and simple machine interlocking. Combined with a LOGO! base module, it replaces traditional relay control circuits at low cost — without any 24 V level conversion stage.
Q8: Which approvals does the product hold?
It complies with VDE 0631 and holds CSA, UL and FM approvals plus marine approval, is developed per the IEC 61131 programmable controller standard and carries the UKCA mark. EMC emissions meet EN 55011 limit class B, allowing direct use in residential areas.